Performance analysis on industrial refrigeration system integrated with encapsulated PCM-based cool thermal energy storage system
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cool thermal energy storage (CTES) is an advanced energy technology that has recently attracted increasing interest for industrial refrigeration applications such as process cooling, food preservation and building air conditioning systems. An experimental investigation on the performance of an industrial refrigeration system integrated with encapsulated phase change material (PCM)-based CTES system is carried out in the present work. In the experimental set-up a vertical storage tank is integrated with the evaporator of the vapour compression refrigeration system. Effect of the inlet temperature of heat transfer fluid (HTF) on the temperature variation of the PCM and the HTF in the storage tank and the performance parameters namely average rate of charging, energy stored, specific energy consumption (SEC) of the chiller with and without storage system are studied in detail. The effect of porosity variation in the storage tank is also studied. A 1°C decrease in evaporator temperature results in about 3–4% increase in SEC and 1°C decrease in condensing temperature leads to 2.25–3.25% decrease in SEC. The range of HTF inlet temperature and porosity values for optimum performance is reported. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on phase change energy storage: materials and applications
Farid, M. M., Khudhair, A. M., Razack, S. A. K., & Al-Hallaj, S. (2004) · Energy Conversion and Management · doi:10.1016/j.enconman.2003.09.015 · Cited by 3,097
Cited by
A Comprehensive Review of Thermal Energy Storage
Sarbu, I., & Sebarchievici, C. (2018) · Sustainability · doi:10.3390/su10010191 · Cited by 1,311
“Distributed systems are mostly in the range of a few to tens of kW. TES systems based on sensible heat storage offer a storage capacity ranging from 10 to 50 kWh/t and storage efficiencies between 50 and 90%, depending on the specific heat of the storage medium and thermal insulation technologies.”
Review on phase change materials (PCMs) for cold thermal energy storage applications
Oró, E., de Gracia, A., Castell, A., Farid, M. M., & Cabeza, L. F. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.03.058 · Cited by 1,144
A review of available methods and development on energy storage; technology update
Mahlia, T. M. I., Saktisahdan, T. J., Jannifar, A., Hasan, M. H., & Matseelar, H. S. C. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.01.068 · Cited by 871
Advances in thermal energy storage: Fundamentals and applications
Ali, H. M., Rehman, T.-U., Arıcı, M., Said, Z., Duraković, B., Mohammed, H. I., Kumar, R., Rathod, M. K., Buyukdagli, O., & Teggar, M. (2024) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2023.101109 · Cited by 457
Review of solar cooling methods and thermal storage options
Chidambaram, L. A., Ramana, A. S., Kamaraj, G., & Velraj, R. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.04.018 · Cited by 255
Self-citationHe, Q., Wang, S., Tong, M., & Liu, Y. (2012) · Energy Conversion and Management · doi:10.1016/j.enconman.2012.04.010 · Cited by 250
“It has attracted great interest in recent years [3–6].”
BackgroundReview on cold thermal energy storage applied to refrigeration systems using phase change materials
Selvnes, H., Allouche, Y., Manescu, R. I., & Hafner, A. (2021) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2020.100807 · Cited by 245
Senobar, H., Aramesh, M., & Shabani, B. (2020) · Journal of Energy Storage · doi:10.1016/j.est.2020.101911 · Cited by 111
Metadata
- Authors
- Cheralathan, M., Velraj, R., & Renganarayanan, S.
- Venue
- International Journal of Energy Research
- Publisher
- Hindawi Limited
- Published
- 2007
- Volume
- 31
- Issue
- 14
- Pages
- 1398-1413
- ISSN
- 0363-907X (ISSN-L)
- 1099-114X
- OpenAlex
- W2074383952
- Cited by
- 108
- References
- 1
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.