The DOI matches its Crossref record.
Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards
Abstract
Organic contaminant exchange kinetics between semipermeable membrane devices (SPMDs) and water were studied in two suspensions of estuarine and marine sediments under conditions of high and low turbulence over a period of 56 d. Prior to exposure, the SPMDs were spiked with a number of exposure standards not occurring in the environment. The release rate of these compounds was used as an independent measure of the exchange kinetics between the SPMD and water. The uptake rates of chlorobenzenes, polychlorinated biphenyls, (PCBs) and polycyclic aromatic hydrocarbons (PAHs) were lower by a factor of three under conditions of low turbulence. For compounds with a log octanol–water partition coefficient (Kow) > 5.5 the uptake rate was constant during the entire period. Within each compound class, uptake rate constants correlated well with log Kow. The uptake rate constants of PAHs were lower than those of PCBs and chlorobenzenes by a factor of 10, but these estimates probably are artificially low due to an overestimation of the aqueous PAH concentrations. Release rate constants of the exposure standards fell within the range of the uptake rate constants of chlorobenzenes and PCBs, although with poor precision. Suggestions for improving the measurement of exchange rate constants of exposure standards are presented. The role of triolein in the exchange kinetics is shown to be minor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fish bioaccumulation and biomarkers in environmental risk assessment: a review
van der Oost, R., Beyer, J., & Vermeulen, N. P. E. (2003) · Environmental Toxicology and Pharmacology · doi:10.1016/s1382-6689(02)00126-6 · Cited by 4,895
Occurrence of some organic UV filters in wastewater, in surface waters, and in fish from Swiss lakes
Balmer, M. E., Buser, H.-R., Müller, M. D., & Poiger, T. (2005) · Environmental Science & Technology · doi:10.1021/es040055r · Cited by 779
Alvarez, D. A., Petty, J. D., Huckins, J. N., Jones-Lepp, T. L., Getting, D. T., Goddard, J. P., & Manahan, S. E. (2004) · Environmental Toxicology and Chemistry · doi:10.1897/03-603 · Cited by 699
Calibration and use of the polar organic chemical integrative sampler—a critical review
Harman, C., Allan, I. J., & Vermeirssen, E. L. M. (2012) · Environmental Toxicology and Chemistry · doi:10.1002/etc.2011 · Cited by 300
Adams, R. G., Lohmann, R., Fernandez, L. A., MacFarlane, J. K., & Gschwend, P. M. (2007) · Environmental Science & Technology · doi:10.1021/es0621593 · Cited by 287
Metadata
- Authors
- Booij, K., Sleiderink, H. M., & Smedes, F.
- Venue
- Environmental Toxicology and Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-07-01
- Volume
- 17
- Issue
- 7
- Pages
- 1236-1245
- ISSN
- 0730-7268 (ISSN-L)
- 1552-8618
- OpenAlex
- W2151164931
- Cited by
- 307
- References
- 0
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards. https://app.cochat.ai/papers/10.1002/etc.5620170707
- The paper
- Booij, K., Sleiderink, H. M., & Smedes, F. (1998). Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards. Environmental Toxicology and Chemistry. https://doi.org/10.1002/etc.5620170707
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.