Assessing the influence of scanner background noise on auditory processing. I. An fMRI study comparing three experimental designs with varying degrees of scanner noise
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We compared two experimental designs aimed at minimizing the influence of scanner background noise (SBN) on functional MRI (fMRI) of auditory processes with one conventional fMRI design. Ten subjects listened to a series of four one‐syllable words and had to decide whether two of the words were identical. This was contrasted with a no‐stimulus control condition. All three experimental designs had a duration of ∼17 min: 1) a behavior interleaved gradients (BIG; Eden et al. [1999] J Magn Reson Imaging 41:13–20) design (repetition time, TR, = 6 s), where stimuli were presented during the SBN‐free periods between clustered volume acquisitions (CVA); 2) a sparse temporal sampling technique (STsamp; e.g., Gaab et al., [2003] Neuroimage 19:1417–1426) acquiring only one set of slices following each of the stimulations with a 16‐s TR and jittered delay times between stimulus offset and image acquisition; and 3) an event‐related design with continuous scanning (ERcont) using the stimulation design of STsamp but with a 2‐s TR. The results demonstrated increased signal within Heschl's gyrus for the STsamp and BIG‐CVA design in comparison to ERcont as well as differences in the overall functional anatomy among the designs. The possibility to obtain a time course of activation as well as the full recovery of the stimulus‐ and SBN‐induced hemodynamic response function signal and lack of signal suppression from SBN during the STsamp design makes this technique a powerful approach for conducting auditory experiments using fMRI. Practical strengths and limitations of the three auditory acquisition paradigms are discussed. Hum Brain Mapp, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Thresholding of statistical maps in functional neuroimaging using the false discovery rate
Genovese, C. R., Lazar, N. A., & Nichols, T. (2002) · NeuroImage · doi:10.1006/nimg.2001.1037 · Cited by 4,923 · cited 1×
“The random-effects analyses were corrected for multiple comparisons using the false discovery rate [e.g., Genovese et al., 2002].”
MethodMagnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Human Brain Language Areas Identified by Functional Magnetic Resonance Imaging
Binder, J. R., Frost, J. A., Hammeke, T. A., Cox, R. W., Rao, S. M., & Prieto, T. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-01-00353.1997 · Cited by 1,424
Human temporal lobe activation by speech and nonspeech sounds
Binder, J. R. (2000) · Cerebral Cortex · doi:10.1093/cercor/10.5.512 · Cited by 1,345 · cited 1×
“…the view that hemispheric specialization is not apparent in early or primary cortical r 712 r processing, but lateralized (in this case left-lateralized for verbal material) in later or secondary cortical processing [e.g., Binder et al., 1997, 2000; Giraud and Price, 2001; Poeppel et al., 2004].”
BackgroundPlanning and spatial working memory: A positron emission tomography study in humans
Owen, A. M., Doyon, J., Petrides, M., & Evans, A. C. (1996) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1996.tb01219.x · Cited by 450 · cited 1×
“Several studies have demonstrated caudate activations in working memory tasks [Lewis et al., 2004; Owen et al., 1996; Postle and D’Esposito 1999a,b; Speck et al., 2003].”
BackgroundKonrad, K., Neufang, S., Hanisch, C., Fink, G. R., & Herpertz-Dahlmann, B. (2006) · Biological Psychiatry · doi:10.1016/j.biopsych.2005.08.013 · Cited by 335
Development of attentional networks: an fMRI study with children and adults
Konrad, K., Neufang, S., Thiel, C. M., Specht, K., Hanisch, C., Fan, J., Herpertz-Dahlmann, B., & Fink, G. R. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.065 · Cited by 332 · cited 1×
“Studies showing differences in the functional anatomy between healthy young adult subjects and these populations may have neglected possible differences in general and selective attention to the SBN [e.g., Konrad et al., 2005, 2006; Townsend et al., 2006].”
BackgroundDerrfuss, J., Brass, M., & Yves von Cramon, D. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.007 · Cited by 312 · cited 1×
“Similar network components were previously reported by several studies examining auditory and verbal working memory [e.g., Derrfuss et al., 2004; Grasby et al., 1994; LaBar et al., 1999].”
ResultThe Constraints Functional Neuroimaging Places on Classical Models of Auditory Word Processing
Giraud, A. L., & Price, C. J. (2001) · Journal of Cognitive Neuroscience · doi:10.1162/08989290152541421 · Cited by 163 · cited 2×
“…the view that hemispheric specialization is not apparent in early or primary cortical r 712 r processing, but lateralized (in this case left-lateralized for verbal material) in later or secondary cortical processing [e.g., Binder et al., 1997, 2000; Giraud and Price, 2001; Poeppel et al., 2004].”
Background
Cited by
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Self-citationLonsdorf, T. B., Menz, M. M., Andreatta, M., Fullana, M. A., Golkar, A., Haaker, J., Heitland, I., Hermann, A., Kuhn, M., Kruse, O., et al. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.02.026 · Cited by 837
“Picture qualities such as brightness and contrasts deviate between screens and projectors, the perception of sounds might be affected by scanner noise (Gaab et al., 2007).”
Obleser, J., Wise, R. J. S., Alex Dresner, M., & Scott, S. K. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.4663-06.2007 · Cited by 354
Meinzer, M., Antonenko, D., Lindenberg, R., Hetzer, S., Ulm, L., Avirame, K., Flaisch, T., & Flöel, A. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.4812-11.2012 · Cited by 287
Pediatric neuroimaging in early childhood and infancy: challenges and practical guidelines
Raschle, N., Zuk, J., Ortiz‐Mantilla, S., Sliva, D. D., Franceschi, A., Grant, P. E., Benasich, A. A., & Gaab, N. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06457.x · Cited by 264
Self-citation
Metadata
- Authors
- Gaab, N., Gabrieli, J. D. E., & Glover, G. H.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2006-11
- Volume
- 28
- Issue
- 8
- Pages
- 703-720
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2132897896
- Cited by
- 122
- References
- 11
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing the influence of scanner background noise on auditory processing. I. An fMRI study comparing three experimental designs with varying degrees of scanner noise. https://app.cochat.ai/papers/10.1002/hbm.20298
- The paper
- Gaab, N., Gabrieli, J. D. E., & Glover, G. H. (2007). Assessing the influence of scanner background noise on auditory processing. I. An fMRI study comparing three experimental designs with varying degrees of scanner noise. Human Brain Mapping. https://doi.org/10.1002/hbm.20298
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.