Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 378

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Source‐based morphometry: The use of independent component analysis to identify gray matter differences with application to schizophrenia

Open access
Xu, Lai, Groth, Karyn M., Pearlson, Godfrey, Schretlen, David J., Calhoun, Vince D.·2009·Human Brain Mapping

Abstract

We present a multivariate alternative to the voxel‐based morphometry (VBM) approach called source‐based morphometry (SBM), to study gray matter differences between patients and healthy controls. The SBM approach begins with the same preprocessing procedures as VBM. Next, independent component analysis is used to identify naturally grouping, maximally independent sources. Finally, statistical analyses are used to determine the significant sources and their relationship to other variables. The identified “source networks,” groups of spatially distinct regions with common covariation among subjects, provide information about localization of gray matter changes and their variation among individuals. In this study, we first compared VBM and SBM via a simulation and then applied both methods to real data obtained from 120 chronic schizophrenia patients and 120 healthy controls. SBM identified five gray matter sources as significantly associated with schizophrenia. These included sources in the bilateral temporal lobes, thalamus, basal ganglia, parietal lobe, and frontotemporal regions. None of these showed an effect of sex. Two sources in the bilateral temporal and parietal lobes showed age‐related reductions. The most significant source of schizophrenia‐related gray matter changes identified by SBM occurred in the bilateral temporal lobe, while the most significant change found by VBM occurred in the thalamus. The SBM approach found changes not identified by VBM in basal ganglia, parietal, and occipital lobe. These findings show that SBM is a multivariate alternative to VBM, with wide applicability to studying changes in brain structure. Hum Brain Mapp, 2009. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hbm.20540

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 378

Metadata

Authors
Xu, L., Groth, K. M., Pearlson, G., Schretlen, D. J., & Calhoun, V. D.
Venue
Human Brain Mapping
Publisher
Wiley
Published
2008-02-11
Volume
30
Issue
3
Pages
711-724
ISSN
  • 1065-9471 (ISSN-L)
  • 1097-0193
OpenAlex
W2119720840
Cited by
378
References
6
FWCI
4.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Source‐based morphometry: The use of independent component analysis to identify gray matter differences with application to schizophrenia. https://app.cochat.ai/papers/10.1002/hbm.20540
The paper
Xu, L., Groth, K. M., Pearlson, G., Schretlen, D. J., & Calhoun, V. D. (2009). Source‐based morphometry: The use of independent component analysis to identify gray matter differences with application to schizophrenia. Human Brain Mapping. https://doi.org/10.1002/hbm.20540

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.