Detection and localization of hippocampal activity using beamformers with MEG: A detailed investigation using simulations and empirical data
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The ability to detect neuronal activity emanating from deep brain structures such as the hippocampus using magnetoencephalography has been debated in the literature. While a significant number of recent publications reported activations from deep brain structures, others reported their inability to detect such activity even when other detection modalities confirmed its presence. In this article, we relied on realistic simulations to show that both sides of this debate are correct and that these findings are reconcilable. We show that the ability to detect such activations in evoked responses depends on the signal strength, the amount of brain noise background, the experimental design parameters, and the methodology used to detect them. Furthermore, we show that small signal strengths require contrasts with control conditions to be detected, particularly in the presence of strong brain noise backgrounds. We focus on one localization technique, the adaptive spatial filter (beamformer), and examine its strengths and weaknesses in reconstructing hippocampal activations, in the presence of other strong brain sources such as visual activations, and compare the performance of the vector and scalar beamformers under such conditions. We show that although a weight‐normalized beamformer combined with a multisphere head model is not biased in the presence of uncorrelated random noise, it can be significantly biased in the presence of correlated brain noise. Furthermore, we show that the vector beamformer performs significantly better than the scalar under such conditions. We corroborate our findings empirically using real data and demonstrate our ability to detect and localize such sources. Hum Brain Mapp, 2011. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“Such systems have a reduced sensitivity to deep sources [Hamalainen et al., 1993; Vrba and Robinson, 2001] compared to a radial gradiometer system with a 50-mm baseline, which may partially explain the failure of some studies to detect deep sources.”
BackgroundVan Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“The bias of the UG constrained beamformer has been corrected in the literature by dividing the source power by the noise power [Van Veen et al., 1997], resulting in a quantity described in units of pseudo-z scores [Robinson and Vrba, 1999].”
MethodSignal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716 · cited 1×
“Such systems have a reduced sensitivity to deep sources [Hamalainen et al., 1993; Vrba and Robinson, 2001] compared to a radial gradiometer system with a 50-mm baseline, which may partially explain the failure of some studies to detect deep sources.”
BackgroundBreier, J. I., Simos, P. G., Zouridakis, G., & Papanicolaou, A. C. (1998) · Journal of Clinical and Experimental Neuropsychology · doi:10.1076/jcen.20.6.782.1116 · Cited by 60
Cited by
Brain responses in humans reveal ideal observer-like sensitivity to complex acoustic patterns
Barascud, N., Pearce, M. T., Griffiths, T. D., Friston, K. J., & Chait, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508523113 · Cited by 296
Episodic sequence memory is supported by a theta-gamma phase code
Heusser, A. C., Poeppel, D., Ezzyat, Y., & Davachi, L. (2016) · Nature Neuroscience · doi:10.1038/nn.4374 · Cited by 290
Deep brain activities can be detected with magnetoencephalography
Pizzo, F., Roehri, N., Medina Villalon, S., Trébuchon, A., Chen, S., Lagarde, S., Carron, R., Gavaret, M., Giusiano, B., McGonigal, A., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08665-5 · Cited by 225
Attal, Y., & Schwartz, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059856 · Cited by 199
“However, it could be interesting, as shown in the simulations of [15], to quantify the SNR threshold at which the method is no longer able to detect the simulated activities or how the DBA addresses ongoing oscillating data.”
BackgroundFuentemilla, L., Barnes, G. R., Düzel, E., & Levine, B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.029 · Cited by 114
“MEG recordings were made in a magnetically shielded room by using a 150-channel CTF system with SQUID-based axial gradiometers (VSM MedTech Ltd., Coquitlam, BC, Canada).”
Influential
Metadata
- Authors
- Quraan, M. A., Moses, S. N., Hung, Y., Mills, T., & Taylor, M. J.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2011-04-11
- Volume
- 32
- Issue
- 5
- Pages
- 812-827
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2045706451
- Cited by
- 117
- References
- 4
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and localization of hippocampal activity using beamformers with MEG: A detailed investigation using simulations and empirical data. https://app.cochat.ai/papers/10.1002/hbm.21068
- The paper
- Quraan, M. A., Moses, S. N., Hung, Y., Mills, T., & Taylor, M. J. (2011). Detection and localization of hippocampal activity using beamformers with MEG: A detailed investigation using simulations and empirical data. Human Brain Mapping. https://doi.org/10.1002/hbm.21068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.