CoChat

Reliability of neuroanatomical measurements in a multisite longitudinal study of youth at risk for psychosis

Open access
Cannon, Tyrone D., Sun, Frank, McEwen, Sarah Jacobson, Papademetris, Xenophon, He, George, van Erp, Theo G.M., Jacobson, Aron, Bearden, Carrie E., Walker, Elaine, Hu, Xiaoping, Zhou, Lei, Seidman, Larry J., Thermenos, Heidi W., Cornblatt, Barbara, Olvet, Doreen M., Perkins, Diana, Belger, Aysenil, Cadenhead, Kristin, Tsuang, Ming, Mirzakhanian, Heline, Addington, Jean, Frayne, Richard, Woods, Scott W., McGlashan, Thomas H., Constable, R. Todd, Qiu, Maolin, Mathalon, Daniel H., Thompson, Paul, Toga, Arthur W. · 2014 · Human Brain Mapping
Cited by 78

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Multisite longitudinal neuroimaging designs are used to identify differential brain structural change associated with onset or progression of disease. The reliability of neuroanatomical measurements over time and across sites is a crucial aspect of power in such studies. Prior work has found that while within‐site reliabilities of neuroanatomical measurements are excellent, between‐site reliability is generally more modest. Factors that may increase between‐site reliability include standardization of scanner platform and sequence parameters and correction for between‐scanner variations in gradient nonlinearities. Factors that may improve both between‐ and within‐site reliability include use of registration algorithms that account for individual differences in cortical patterning and shape. In this study 8 healthy volunteers were scanned twice on successive days at 8 sites participating in the North American Prodrome Longitudinal Study (NAPLS). All sites employed 3 Tesla scanners and standardized acquisition parameters. Site accounted for 2 to 30% of the total variance in neuroanatomical measurements. However, site‐related variations were trivial (<1%) among sites using the same scanner model and 12‐channel coil or when correcting for between‐scanner differences in gradient nonlinearity and scaling. Adjusting for individual differences in sulcal‐gyral geometries yielded measurements with greater reliabilities than those obtained using an automated approach. Neuroimaging can be performed across multiple sites at the same level of reliability as at a single site, achieving within‐ and between‐site reliabilities of 0.95 or greater for gray matter density in the majority of voxels in the prefrontal and temporal cortical surfaces as well as for the volumes of most subcortical structures. Hum Brain Mapp 35:2424–2434, 2014. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hbm.22338

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Cannon, T. D., Sun, F., McEwen, S. J., Papademetris, X., He, G., van Erp, T. G. M., Jacobson, A., Bearden, C. E., Walker, E., Hu, X., Zhou, L., Seidman, L. J., Thermenos, H. W., Cornblatt, B., Olvet, D. M., Perkins, D., Belger, A., Cadenhead, K., Tsuang, M., Mirzakhanian, H., Addington, J., Frayne, R., Woods, S. W., McGlashan, T. H., Constable, R. T., Qiu, M., Mathalon, D. H., Thompson, P., & Toga, A. W.
Venue
Human Brain Mapping
Publisher
Wiley
Published
2013-08-24
Volume
35
Issue
5
Pages
2424-2434
ISSN
  • 1065-9471 (ISSN-L)
  • 1097-0193
OpenAlex
W1697966374
Cited by
78
References
5
FWCI
3.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.