The DOI matches its Crossref record.
Immunohistochemical detection of chloride/bicarbonate anion exchangers in human liver
Open accessAbstract
Sodium-independent Cl−/HCO 3 − exchange activity has been observed in isolated rat hepatocytes and intrahepatic bile duct epithelial cells, where it is involved in intracellular pH regulation and, possibly, biliary bicarbonate secretion. Monoclonal antibodies to the membrane domain of human chloride/bicarbonate anion exchanger proteins, AE1 and AE2, were prepared so that we might determine by immunohistochemical methods the presence and location of these antiporters in the human liver. To obtain the antibody against AE1, we immunized mice with injections of washed human erythrocytes. The selected monoclonal antibody was found to be specific for the 17-kD proteolytic membrane fragment of AE1 protein. The antibody to AE2 was produced with a 14-mer synthetic peptide, whose sequence corresponds specifically to amino acid residues 871 to 884 in the deduced primary structure of human kidney AE2 protein. When the monoclonal antibody to AE2 peptide was employed for the immunohistochemical study of liver specimens (by both immunofluorescence and immunoperoxidase), a clearly defined staining was present at the canalicular membrane of hepatocytes, as well as the luminal side of the membrane of bile duct epithelial cells from small and medium-sized bile ducts. No staining was observed in the liver parenchyma with the monoclonal antibody to AE1, which instead strongly decorated the erythrocytes in liver blood vessels. We conclude that AE2 immunoreactivity is present in human liver, where it localizes very specifically to the membrane regions, which appear most probably involved in the transport of bicarbonate to bile (i.e., the canalicular membrane of hepatocytes and the apical side of epithelial cells of small and medium bile ducts). (Hepatology 1994;19:1400-1406.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bile salt transporters: molecular characterization, function, and regulation
Trauner, M., & Boyer, J. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00027.2002 · Cited by 999
Beuers, U., Hohenester, S., de Buy Wenniger, L. J. M., Kremer, A. E., Jansen, P. L. M., & Elferink, R. P. J. O. (2010) · Hepatology · doi:10.1002/hep.23810 · Cited by 351
Banales, J. M., Sáez, E., Úriz, M., Sarvide, S., Urribarri, A. D., Splinter, P., Tietz Bogert, P. S., Bujanda, L., Prieto, J., Medina, J. F., et al. (2012) · Hepatology · doi:10.1002/hep.25691 · Cited by 250
Self-citationBoyer, J. L. (2013) · Comprehensive Physiology · doi:10.1002/j.2040-4603.2013.tb00519.x · Cited by 124
Melero, S., Spirlì, C., Zsembery, Á., Medina, J. F., Joplin, R. E., Duner, E., Zuin, M., Neuberger, J. M., Prieto, J., & Strazzabosco, M. (2002) · Hepatology · doi:10.1053/jhep.2002.33634 · Cited by 107
Self-citation
Metadata
- Authors
- Martínez-Ansó, E., Castillo, J. E., Díez, J., Medina, J. F., & Prieto, J.
- Venue
- Hepatology
- Published
- 1994-06
- Volume
- 19
- Issue
- 6
- Pages
- 1400-1406
- ISSN
- 0270-9139 (ISSN-L)
- OpenAlex
- W1974778418
- Cited by
- 172
- References
- 0
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immunohistochemical detection of chloride/bicarbonate anion exchangers in human liver. https://app.cochat.ai/papers/10.1002/hep.1840190613
- The paper
- Martínez-Ansó, E., Castillo, J. E., Díez, J., Medina, J. F., & Prieto, J. (1994). Immunohistochemical detection of chloride/bicarbonate anion exchangers in human liver. Hepatology. https://doi.org/10.1002/hep.1840190613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.