Interobserver and interquipment variability of echo-doppler examination of the portal vein: Effect of a cooperative training program

Sabbà, Carlo, Merkel, Carlo, Zoli, Marco, Ferraioli, Giovanna, Gaiani, Stefano, Sacerdoti, David, Bolondi, Luigi·1995·Hepatology

Abstract

The aim of this study was to assess the interobserver, interequipment, and time-dependent variabilities of echo-Doppler measurements of portral blood flow velocity (PBV), portal vein diameters (PVDs) and their derived parameters, portal blood flow (PBF), and congestion index (CI) in cirrhotic patients. The influence of a cooperative training program of the opeators on the reproductibility of the results was also investigated. The echo-Doppler parameters were independently measured in 15 patients by four skilled operators, using four echo-Doppler machines (Acuson, ATL, Hitachi-Esaote, Toshiba. Eight of the 15 patients were restudied after 15 days by the same operators using only one machine. Significantly different values of PBV, PBF, and CI were obtained. PBV variance was equipment-related (32%) and operator-related in a smaller portion (5%). No systemiatic effect related to the time of investigation was found. After training to define a precise protocol, new measurements were performed by four operators on 8 different patients. No significant differences were found among the operators for any of the parameters and the 95% confidence limits (CL) and coefficients of variation (CV) of PBV showed a marked decrease (CL from ±26.4% to ±15.6%). These results indicate that (1) a significant systematic vaiability exists between Doppler measurements with different equipment; (2) there is no significant time-dependent systematic variability of Doppler measurements; and (3) a cooperative training program reduces the interobserver variability for direct measurements, such as PBV. (Hepatology 1995;21:428-433.)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.1840210225

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 159

Metadata

Authors
Sabbà, C., Merkel, C., Zoli, M., Ferraioli, G., Gaiani, S., Sacerdoti, D., & Bolondi, L.
Venue
Hepatology
Published
1995-02
Volume
21
Issue
2
Pages
428-433
ISSN
0270-9139 (ISSN-L)
OpenAlex
W2012109088
Cited by
159
References
1
FWCI
7.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interobserver and interquipment variability of echo-doppler examination of the portal vein: Effect of a cooperative training program. https://app.cochat.ai/papers/10.1002/hep.1840210225
The paper
Sabbà, C., Merkel, C., Zoli, M., Ferraioli, G., Gaiani, S., Sacerdoti, D., & Bolondi, L. (1995). Interobserver and interquipment variability of echo-doppler examination of the portal vein: Effect of a cooperative training program. Hepatology. https://doi.org/10.1002/hep.1840210225

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.