Cited by 232Inflammatory Bowel DiseaseUltrasound in Clinical ApplicationsUltrasound Imaging and Elastography

The DOI matches its Crossref record; 205 of the 205 references it cites were found in a registry or an index.

EFSUMB Recommendations and Clinical Guidelines for Intestinal Ultrasound (GIUS) in Inflammatory Bowel Diseases

Open access

Abstract

The accuracy and usefulness of gastrointestinal ultrasound (GIUS) for detecting activity and complications of inflammatory bowel diseases (IBD), has been reported in studies, promoting this technique as an important tool for the management of IBD patients. Whilst well recognised by international guidelines, standardization and general agreement in the definition of the luminal and extra-intestinal features, still need to be well defined. A task force group of 17 experts in GIUS faced this issue, by developing recommendations and clinical guidelines for the use of GIUS in IBD, under the auspices of EFSUMB. This article presents the consensus on the current data on sonographic features of IBD and summarises the accuracy of different sonographic modalities for the management of IBD patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0043-125329

Cites

205 of 205 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • AI models for automatically detecting inflammatory-related changes could greatly aid in standardising image interpretation and scoring in clinical practice and trials, ultimately improving patient management.

    “Further studies are warranted, but AI models for automatically detecting inflammatory-related changes could greatly aid in standardising image interpretation and scoring in clinical practice and trials, ultimately improving patient management.47-49”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 14

  1. Annese V, Daperno M, Rutter MD. European Crohn's and Colitis Organi- sation European evidence based consensus for endoscopy in inflamma- tory bowel disease. J Crohns Colitis 2013; 7: 982 -1018
  2. Howick J, Chalmers I, Glasziou P et al. The Oxford Levels of Evidence 2. OCEBM Levels of Evidence Working Group, Oxford Centre for Eviden- ceBased Medicine. Available from: 2009 http://www.cebm.net/index. aspx?o=5653
  3. Nylund K, Leh S, Immervoll H et al. Crohn's disease: Comparison of in vitro ultrasonographic images and histology. Scand J Gastroenterol 2008; 43: 719 -726
  4. Jenssen C, Tuma J, Moller K et al. Ultrasound artifacts and their diagnos- tic significance in internal medicine and gastroenterology -part 2: color and spectral Doppler artifacts. Z Gastroenterol 2016; 54: 569 -578
  5. Dietrich CF, Zeuzem S, Caspary WF et al. Sonographische Lymphkno- tendarstellung im Abdomen bei gesunden Probanden. Ultraschall in Med 1998; 19: 265 -269
  6. Maconi G, Di Sabatino A, Ardizzone S et al. Prevalence and clinical sig- nificance of sonographic detection of enlarged regional lymph nodes in Crohn's disease. Scand J Gastroenterol 2005; 40: 1328 -1333
  7. Dietrich CF, Hocke M, Jenssen C. Ultrasound for abdominal lymphade- nopathy. Dtsch Med Wochenschr 2013; 138: 1001 -1018
  8. Cosnes J, Cattan S, Blain A et al. Long-term evolution of disease beha- viour of Crohn's disease. Inflamm Bowel Dis 2002; 8: 244 -250
  9. Dignass A, Van AsscheG, Lindsay JO et al. European Crohn's and Colitis Organisation (ECCO). The second European evidence-based Consensus on the diagnosis and management of Crohn's disease: Current man- agement. J Crohns Colitis 2010; 4: 28 -62
  10. Nylund K, Ødegaard S, Hausken T et al. Sonography of the small intes- tine. World J Gastroenterol 2009; 15: 1319 -1330
  11. Schwerk WB, Beckh K, Raith M. A prospective evaluation of high reso- lution sonography in the diagnosis of inflammatory bowel diasease. Eur J Gastroenterol Hepatol 1992; 4: 173 -182
  12. Maconi G, Sampietro GM, Ardizzone S et al. Ultrasonographic detec- tion of toxic megacolon in inflammatory bowel diseases. Dig Dis Sci 2004; 49: 138 -142
  13. Mathis G, Metzler J. Sonography in salmonella enterocolitis. Ultraschall in Med 1992; 13: 106 -109
  14. Nuernberg D, Ignee A, Dietrich CF. Current status of ultrasound in gastroenterology-bowel and upper gastrointestinal tract-part 2. Z Gastroenterol 2008; 46: 355 -366

Cited by

Sorted by citations

Metadata

Authors
Maconi, G., Nylund, K., Ripolles, T., Calabrese, E., Dirks, K., Dietrich, C., Hollerweger, A., Sporea, I., Saftoiu, A., Maaser, C., Hausken, T., Higginson, A., Nürnberg, D., Pallotta, N., Romanini, L., Serra, C., & Gilja, O.
Affiliations
  • Luigi Sacco Hospital (IT)
  • Haukeland University Hospital (NO)
  • Radiology, Hospital Universitario Doctor Peset, Valencia, Spain
  • University of Rome Tor Vergata (IT)
  • Rems-Murr-Klinikum (DE)
  • Caritas-Krankenhaus Bad Mergentheim (DE)
  • Department of Radiology, Hospital Barmherzige Brüder, Salzburg, Austria
  • Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
  • Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova, Romania
  • Klinikum Lüneburg (DE)
  • Queen Alexandra Hospital (GB)
  • Gastroenterology, Ruppiner Kliniken, Neuruppin, Germany
  • Sapienza University of Rome (IT)
  • Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia (IT)
  • IRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola (IT)
Venue
Ultraschall in der Medizin - European Journal of Ultrasound
Published
2018-03-22
Volume
39
Issue
03
Pages
304-317
ISSN
  • 0172-4614 (ISSN-L)
  • 1438-8782
OpenAlex
W2793022594
Cited by
232
References
205
Citations by year
2026: 27 · 2025: 31 · 2024: 35 · 2023: 39 · 2022: 32 · 2021: 25 · 2020: 24 · 2019: 16 · 2018: 3
FWCI
10.43
Type
journal article
Language
de
Open access
Locations
  • Ultraschall in der Medizin - European Journal of Ultrasound (publishedVersion)
  • PubMed (publishedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion, other-oa)
  • Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Gastroenterology › Inflammatory Bowel Disease
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
Keywords
gastrointestinal ultrasound, intestinal ultrasound, inflammatory bowel disease, Crohn's disease, ulcerative colitis, sonographic features, extraintestinal manifestations, disease activity assessment, diagnostic accuracy, clinical guidelines
MeSH terms
Humans, Intestines, Ultrasonography, Inflammatory Bowel Diseases

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review