Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The international normalized ratio calibrated for cirrhosis (INRliver) normalizes prothrombin time results for model for end‐stage liver disease calculation†

Open access
Tripodi, Armando, Chantarangkul, Veena, Primignani, Massimo, Fabris, Federica, Dell'Era, Alessandra, Sei, Cinzia, Mannuccio Mannucci, Pier·2007·Hepatology

Abstract

UNLABELLED: The model for end-stage-liver-disease (MELD) is a mathematical score used to prioritize patients for liver transplantation and includes results for creatinine, bilirubin, and prothrombin time (PT) expressed as international normalized ratio (INR). The rationale of using the MELD rests on the assumption that the score would be the same across the country if the methods used to measure the variables yield the same numerical results regardless of the testing laboratory. Evidence was provided that specific methodologies may influence the MELD, and the PT-INR was identified as the most important. This study was designed to provide information on the between-thromboplastin variability and to explore alternatives to obviate such variability. Fifty-seven patients with cirrhosis were selected, and their PTs were measured with 7 thromboplastins. The thromboplastins were previously calibrated by testing plasmas from patients on vitamin K antagonists and healthy subjects to assign the international sensitivity index (ISI(vka)) needed to convert PT into INR. Each of the thromboplastins was also assigned an ISI(liver) by substituting in the calibration the plasmas from vitamin K antagonist patients with plasmas from patients with cirrhosis. INR and MELD values for individual patients were calculated by using the ISI(vka) or the ISI(liver). The mean INR(vka) obtained with the 7 thromboplastins were significantly different (P < 0.001). Conversely, the mean INR(liver) were not. Similarly, the mean MELD(vka) were significantly different (P < 0.001), but those differences were abrogated for the MELD(liver). CONCLUSION: The alternative thromboplastin calibration using plasmas from patients with cirrhosis instead of from vitamin K antagonist patients is feasible and may resolve the variability of the MELD to prioritize patients for transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.21732

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 196

Metadata

Authors
Tripodi, A., Chantarangkul, V., Primignani, M., Fabris, F., Dell'Era, A., Sei, C., & Mannuccio Mannucci, P.
Venue
Hepatology
Published
2007-08
Volume
46
Issue
2
Pages
520-527
ISSN
0270-9139 (ISSN-L)
OpenAlex
W2121888044
Cited by
196
References
1
FWCI
9.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.