The DOI matches its Crossref record.
Esophageal balloon tamponade versus esophageal stent in controlling acute refractory variceal bleeding: A multicenter randomized, controlled trial
Abstract
Balloon tamponade is recommended only as a “bridge” to definitive therapy in patients with cirrhosis and massive or refractory esophageal variceal bleeding (EVB), but is frequently associated with rebleeding and severe complications. Preliminary, noncontrolled data suggest that a self‐expandable, esophageal covered metal stent (SX‐ELLA Danis; Ella‐CS, Hradec Kralove, Czech Republic) may be an effective and safer alternative to balloon tamponade. We conducted a randomized, controlled trial aimed at comparing esophageal stent versus balloon tamponade in patients with cirrhosis and EVB refractory to medical and endoscopic treatment. Primary endpoint was success of therapy, defined as survival at day 15 with control of bleeding and without serious adverse events (SAEs). Twenty‐eight patients were randomized to Sengstaken‐Blakemore tube (n = 15) or SX‐ELLA Danis stent (n = 13). Patients were comparable in severity of liver failure, active bleeding at endoscopy, and initial therapy. Success of therapy was more frequent in the esophageal stent than in balloon tamponade group (66% vs. 20%; P = 0.025). Moreover, control of bleeding was higher (85% vs. 47%; P = 0.037) and transfusional requirements (2 vs 6 PRBC; P = 0.08) and SAEs lower (15% vs. 47%; P = 0.077) in the esophageal stent group. TIPS was used more frequently in the tamponade group (4 vs. 10; P = 0.12). There were no significant differences in 6‐week survival (54% vs. 40%; P = 0.46). Conclusion: Esophageal stents have greater efficacy with less SAEs than balloon tamponade in the control of EVB in treatment failures. Our findings favor the use of esophageal stents in patients with EVB uncontrolled with medical and endoscopic treatment. (H epatology 2016;63:1957‐1967)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EASL Clinical Practice Guidelines for the management of patients with decompensated cirrhosis
Angeli, P., Bernardi, M., Villanueva, C., Francoz, C., Mookerjee, R. P., Trebicka, J., Krag, A., Laleman, W., & Gines, P. (2018) · Journal of Hepatology · doi:10.1016/j.jhep.2018.03.024 · Cited by 2,905
Self-citationGarcia‐Tsao, G., Abraldes, J. G., Berzigotti, A., & Bosch, J. (2017) · Hepatology · doi:10.1002/hep.28906 · Cited by 2,154
Self-citationKaplan, D. E., Ripoll, C., Thiele, M., Fortune, B. E., Simonetto, D. A., Garcia-Tsao, G., & Bosch, J. (2024) · Hepatology · doi:10.1097/hep.0000000000000647 · Cited by 486
Self-citationManagement of acute upper gastrointestinal bleeding
Stanley, A. J., & Laine, L. (2019) · BMJ · doi:10.1136/bmj.l536 · Cited by 296
Gralnek, I. M., Camus Duboc, M., Garcia-Pagan, J. C., Fuccio, L., Karstensen, J. G., Hucl, T., Jovanovic, I., Awadie, H., Hernandez-Gea, V., Tantau, M., et al. (2022) · Endoscopy · doi:10.1055/a-1939-4887 · Cited by 283
Metadata
- Authors
- Escorsell, À., Pavel, O., Cárdenas, A., Morillas, R., Llop, E., Villanueva, C., Garcia‐Pagán, J. C., Bosch, J., & ; for the Variceal Bleeding Study Group
- Venue
- Hepatology
- Published
- 2016-01-14
- Volume
- 63
- Issue
- 6
- Pages
- 1957-1967
- ISSN
- 0270-9139 (ISSN-L)
- 1527-3350
- OpenAlex
- W2341120407
- Cited by
- 250
- References
- 0
- FWCI
- 10.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Esophageal balloon tamponade versus esophageal stent in controlling acute refractory variceal bleeding: A multicenter randomized, controlled trial. https://app.cochat.ai/papers/10.1002/hep.28360
- The paper
- Escorsell, À., Pavel, O., Cárdenas, A., Morillas, R., Llop, E., Villanueva, C., Garcia‐Pagán, J. C., Bosch, J., & ; for the Variceal Bleeding Study Group. (2016). Esophageal balloon tamponade versus esophageal stent in controlling acute refractory variceal bleeding: A multicenter randomized, controlled trial. Hepatology. https://doi.org/10.1002/hep.28360
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.