CoChat

A prospective study of the utility of plasma biomarkers to diagnose alcoholic hepatitis

Bissonnette, Julien, Altamirano, José, Devue, Cécile, Roux, Olivier, Payancé, Audrey, Lebrec, Didier, Bedossa, Pierre, Valla, Dominique, Durand, François, Ait‐Oufella, Hafid, Sancho‐Bru, Pau, Caballeria, Joan, Ginès, Pere, Boulanger, Chantal M., Bataller, Ramon, Rautou, Pierre‐Emmanuel · 2017 · Hepatology
Cited by 119

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The diagnosis of alcoholic hepatitis (AH) often requires a transjugular liver biopsy (TJLB), a procedure that is not always readily accessible. We analyzed plasma biomarkers to estimate the presence of histological features of AH among patients with clinical suspicion of AH. Using enzyme‐linked immunosorbent assay, we tested M65 and M30 (circulating fragments of cytokeratin‐18) and their respective fraction carried by microvesicles (MVs), CCL20 and TREM1. Leukocyte, platelet, and endothelial‐derived MVs were quantified by way of flow cytometry. Test and validation cohorts prospectively included patients with clinical features of AH undergoing TJLB. In the test cohort, 46 of 83 (55%) patients showed histological features of AH. Age, bilirubin, INR, and creatinine (ABIC) score was B or C in 83%. Patients with histologically proven AH had higher levels of total and MV‐bound M65 and total and MV‐bound M30 and CCL20 than those without (P < 0.001 for all tests). Levels of TREM‐1 and of subpopulations of MVs were not different between groups. M65 and M30 both had an area under the receiver operating characteristics curve of 0.84 to estimate the presence of AH. For M65, a cutoff of 2000 IU/L had a positive predictive value of 91%, whereas a cutoff of 641 IU/L had a negative predictive value of 88%. In the validation cohort, AH was histologically confirmed in 48 of 68 (71%) patients. ABIC score was B or C in 69% of patients. For M65, the above cutoffs had a diagnostic accuracy of 81%. Even better results were obtained in patients with suspicion of severe AH (ABIC B or C) in both cohorts. Conclusion: Plasma levels of cytokeratin‐18 fragments are reliable noninvasive markers of AH. Using the proposed cutoffs for M65, two thirds of TJLB can be avoided, which can be useful in centers where this technique is not readily available. (H epatology 2017;66:555–563).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.29080

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 119

Metadata

Authors
Bissonnette, J., Altamirano, J., Devue, C., Roux, O., Payancé, A., Lebrec, D., Bedossa, P., Valla, D., Durand, F., Ait‐Oufella, H., Sancho‐Bru, P., Caballeria, J., Ginès, P., Boulanger, C. M., Bataller, R., & Rautou, P.
Venue
Hepatology
Published
2017-06-22
Volume
66
Issue
2
Pages
555-563
ISSN
  • 0270-9139 (ISSN-L)
  • 1527-3350
OpenAlex
W2582113473
Cited by
119
References
2
FWCI
9.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.