Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 284

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

The role of ultrasonography and automatic-needle biopsy in outpatient percutaneous liver biopsy

Open access
Lindor, K D, Bru, C, Jorgensen, R A, Rakela, J, Bordas, J M, Gross, J B, Rodes, J, McGill, D B, Reading, C C, James, E M, Charboneau, J W, Ludwig, J, Batts, K P, Zinsmeister, A R · 1996 · Hepatology

Abstract

The risk of complications from percutaneous liver biopsy is low, but discomfort is common and complications require hospitalization in approximately 4% of patients. The optimal method of performing these biopsies is unknown. The goal of our study was to determine whether the use of ultrasonography in the biopsy room immediately prior to or during the procedure would lessen the risk of complications and to compare the safety and efficacy in obtaining tissue by use of a Trucut needle versus an automatic biopsy needle. Between 1992 and 1994, 836 patients were entered into a randomized study (489 in Rochester, MN; 347 in Barcelona, Spain). Patients were randomized immediately prior to liver biopsy into four groups: Trucut needle, or automatic biopsy needle, and with or without ultrasonography. Fisher’s Exact Test and a logistic regression model were also used to assess the effect of needle and ultrasonography on the odds for complications. The four biopsy groups were well-matched at entry with respect to age, sex, underlying liver disease, hemoglobin, prothrombin time, and platelet count. The use of ultrasound was associated with a decreased rate of hospitalization for pain, hypotension, or bleeding (2 vs. 9, P < .05). No difference in safety was found between the two types of needles. The number of passes needed to obtain specimens was similar for all four groups. The average length of the specimen was slightly greater with ultrasonographic-guided biopsies (1.7 mm vs. 1.6 mm, P < .05) and with biopsies obtained using the automatic biopsy needle when compared with the Trucut needle (1.7 mm vs. 1.5 mm, P < .05), but this did not seem to be clinically important. The addition of ultrasonography reduces complications in patients undergoing percutaneous liver biopsy. The type of needle appears to offer little difference in safety or yield of diagnostic tissue. The use of ultrasonography for guidance of percutaneous liver biopsy will lead to a lower rate of complications. The value of this benefit must be weighed against the added cost of ultrasonographic guidance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.510230522

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 284

Metadata

Authors
Lindor, K. D., Bru, C., Jorgensen, R. A., Rakela, J., Bordas, J. M., Gross, J. B., Rodes, J., McGill, D. B., Reading, C. C., James, E. M., Charboneau, J. W., Ludwig, J., Batts, K. P., & Zinsmeister, A. R.
Venue
Hepatology
Published
1996-05
Volume
23
Issue
5
Pages
1079-1083
ISSN
0270-9139 (ISSN-L)
OpenAlex
W2112462093
Cited by
284
References
5
FWCI
3.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The role of ultrasonography and automatic-needle biopsy in outpatient percutaneous liver biopsy. https://app.cochat.ai/papers/10.1002/hep.510230522
The paper
Lindor, K. D., Bru, C., Jorgensen, R. A., Rakela, J., Bordas, J. M., Gross, J. B., Rodes, J., McGill, D. B., Reading, C. C., James, E. M., Charboneau, J. W., Ludwig, J., Batts, K. P., & Zinsmeister, A. R. (1996). The role of ultrasonography and automatic-needle biopsy in outpatient percutaneous liver biopsy. Hepatology. https://doi.org/10.1002/hep.510230522

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.