Accurate preoperative evaluation of liver mass lesions without fine-needle biopsy

Torzilli, Guido, Minagawa, Masami, Takayama, Tadatoshi, Inoue, Kazuto, Hui, Ai-Min, Kubota, Keiichi, Ohtomo, Kuni, Makuuchi, Masatoshi·1999·Hepatology

Abstract

Fine-needle biopsy (FNB) is associated with problems, such as tumor seeding, which are probably underestimated. The aim of this study was to validate prospectively the accuracy of our diagnostic work-up without FNB, for defining indications for surgery in a cohort of patients with focal liver lesions (FLLs). Between January 1997 and December 1998, 160 consecutive patients carrying 225 FLLs admitted to our department were evaluated prospectively. Preoperative diagnoses were established by means of clinical histories, serum tumor marker levels, ultrasonography, and spiral computed tomography (CT). Angiography, magnetic resonance imaging (MRI), and Lipiodol-CT were performed when it was considered necessary to plan the surgical strategy. All the patients underwent surgery and results of pathological examinations were obtained for all of them. The preoperative diagnoses of 221 of the 225 lesions (98.2%) were confirmed, and the indications for liver resection in 156 of the 160 patients (97.5%) were correct. The respective accuracy, sensitivity, specificity, and positive and negative predictive values were 99.6%, 100%, 98.9%, 99.3%, and 100% for diagnosis of hepatocellular carcinoma (HCC); 99.1%, 100%, 98.8%, 96.9%, and 100% for metastases; 99.6%, 100%, 99.5%, 91%, and 100% for cholangiocellular carcinomas (CCCs); all 100% for mixed HCC-CCCs; and 98.7%, 57.1%, 100%, 100%, and 98.6% for benign tumors. In view of these results, the fact that the real risks of FNB have yet to be established and the possibility that tumor seeding has a major impact on patient prognosis, the use of FNB should be drastically limited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hep.510300411

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 316

Metadata

Authors
Torzilli, G., Minagawa, M., Takayama, T., Inoue, K., Hui, A.-M., Kubota, K., Ohtomo, K., & Makuuchi, M.
Venue
Hepatology
Published
1999-10
Volume
30
Issue
4
Pages
889-893
ISSN
0270-9139 (ISSN-L)
OpenAlex
W2037480346
Cited by
316
References
9
FWCI
5.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accurate preoperative evaluation of liver mass lesions without fine-needle biopsy. https://app.cochat.ai/papers/10.1002/hep.510300411
The paper
Torzilli, G., Minagawa, M., Takayama, T., Inoue, K., Hui, A.-M., Kubota, K., Ohtomo, K., & Makuuchi, M. (1999). Accurate preoperative evaluation of liver mass lesions without fine-needle biopsy. Hepatology. https://doi.org/10.1002/hep.510300411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.