The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Potential of turbidity monitoring for measuring the transport of suspended solids in streams
Abstract
Investigating the transport of suspended solids by water sampling usually leads to an underestimation of loads and an unrealistically high sampling frequency is required to properly characterize temporal trends. An alternative method is to use in situ optical turbidimeters to estimate the suspended solids concentration; however, the relationship between turbidity and suspended solids concentration is potentially confounded by variations in particle size, particle composition and water colour. Field measurements, and laboratory measurements using the type of natural material suspended in streamwater, were made to quantify the influences of these factors on nephelometric turbidity (Hach 2100A) and attenuance turbidity (Partech 7000 3RP MKII). The attenuance turbidity was approximately 2.5 times higher than nephelometric turbidity. The turbidity instruments were most sensitive to dispersions with a median diameter of 1.2‐1.4γm. Particle size variation can cause the turbidity to vary by a factor of four for the same concentration of suspended solids. However, the numerous close correlations between turbidity and suspended solids concentration reported previously suggests that either the particle size variations are not usually great, or that particle size variations are often associated with variations in suspended solids concentration. For the same concentration and particle size, organic particles gave attenuance turbidity values two to three times higher than mineral particles. However, shortterm temporal variations from purely organic to purely mineral particle loads are rare in nature, so variations in the percentage of organic matter in the paniculate load will not confound turbidity to this extent. Coloured dissolved organic matter is unlikely to alter the turbidity reading by more than 10%. An adequate relationship between turbidity measured in the field and suspended solids concentration should be expected in most situations. Some variance can be tolerated because a continuous estimate of suspended solids concentration overcomes the problem of infrequent sampling, which is the greatest source of error in the estimation of stream sediment loads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standard methods for the examination of water and wastewater
(2012) · Choice Reviews Online · doi:10.5860/choice.49-6910 · Cited by 14,205
Applied Regression Analysis (2nd ed).
de Carvalho, J. F., Draper, N. R., & Smith, H. (1981) · Journal of the American Statistical Association · doi:10.2307/2287608 · Cited by 3,044
Clarke, G. M., Draper, N. R., & Smith, H. (1982) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982106 · Cited by 1,788
Allen, T. (1981) · Springer eBooks · doi:10.1007/978-1-4899-3063-7 · Cited by 1,472
Origin, Composition, and Flux of Dissolved Organic Carbon in the Hubbard Brook Valley
McDowell, W. H., & Likens, G. E. (1988) · Ecological Monographs · doi:10.2307/2937024 · Cited by 679
Assessing the accuracy of suspended sediment rating curves for a small basin
Walling, D. E. (1977) · Water Resources Research · doi:10.1029/wr013i003p00531 · Cited by 523
Methods for collection and analysis of water samples
(1960) · doi:10.3133/wsp1454 · Cited by 507
Global trends in the nature of organic matter in river suspensions
Ittekkot, V. (1988) · Nature · doi:10.1038/332436a0 · Cited by 356
The effect of particle size on the light attenuation coefficient of natural suspensions
Baker, E. T., & Lavelle, J. W. (1984) · Journal of Geophysical Research: Oceans · doi:10.1029/jc089ic05p08197 · Cited by 338
Optical efficiency factors of some phytoplankters1
Bricaud, A., Morel, A., & Prieur, L. (1983) · Limnology and Oceanography · doi:10.4319/lo.1983.28.5.0816 · Cited by 334
Cited by
Understanding the influence of suspended solids on water quality and aquatic biota
Bilotta, G. S., & Brazier, R. E. (2008) · Water Research · doi:10.1016/j.watres.2008.03.018 · Cited by 1,313
Benchmarking observational uncertainties for hydrology: rainfall, river discharge and water quality
McMillan, H., Krueger, T., & Freer, J. (2012) · Hydrological Processes · doi:10.1002/hyp.9384 · Cited by 522
Dogliotti, A. I., Ruddick, K. G., Nechad, B., Doxaran, D., & Knaeps, E. (2015) · Remote Sensing of Environment · doi:10.1016/j.rse.2014.09.020 · Cited by 509
Webster, A. J., & Cadenasso, M. L. (2020) · Journal of Environmental Management · doi:10.1016/j.jenvman.2020.110307 · Cited by 4
Metadata
- Authors
- Gippel, C. J.
- Venue
- Hydrological Processes
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 9
- Issue
- 1
- Pages
- 83-97
- ISSN
- 0885-6087 (ISSN-L)
- 1099-1085
- OpenAlex
- W2056316473
- Cited by
- 358
- References
- 22
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.