The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
The First Clinical Application of a “Hands-On” Robotic Knee Surgery System
Abstract
The performance of a novel "hands-on" robotic system for total knee replacement (TKR) surgery is evaluated. An integrated robotic system for accurately machining the bone surfaces in TKR surgery is described. Details of the system, comprising an "active constraint" robot, called Acrobot, a "gross positioning" robot, and patient clamps, are provided. The intraoperative protocol and the preoperative, CT-based, planning system are also described. A number of anatomical registration and cutting trials, using plastic bones, are described, followed by results from two preliminary clinical trials, which demonstrate the accuracy achieved in the anatomical registration. Finally, the first clinical trial is described, in which the results of the anatomical registration and bone cutting are seen to be of high quality. The Acrobot system has been successfully used to accurately register and cut the knee bones in TKR surgery. This demonstrates the great potential of a "hands-on" robot for improving accuracy and increasing safety in surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Cited by
Robotic technology in surgery: Past, present, and future
Camarillo, D. B., Krummel, T. M., & Salisbury, J. K. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.025 · Cited by 535
Song, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Application of Artificial Intelligence in Medicine: An Overview
Liu, P.-R., Lu, L., Zhang, J.-Y., Huo, T.-T., Liu, S.-X., & Ye, Z.-W. (2021) · Current Medical Science · doi:10.1007/s11596-021-2474-3 · Cited by 258
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Metadata
- Authors
- Jakopec, M., Harris, S., y Baena, F. R., Gomes, P., Cobb, J. P., & Davies, B.
- Venue
- Computer Aided Surgery
- Publisher
- Taylor & Francis
- Published
- 2001-01-01
- Volume
- 6
- Issue
- 6
- Pages
- 329-339
- ISSN
- 1092-9088 (ISSN-L)
- OpenAlex
- W2095831419
- Cited by
- 225
- References
- 1
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The First Clinical Application of a “Hands-On” Robotic Knee Surgery System. https://app.cochat.ai/papers/10.1002/igs.10023
- The paper
- Jakopec, M., Harris, S., y Baena, F. R., Gomes, P., Cobb, J. P., & Davies, B. (2001). The First Clinical Application of a “Hands-On” Robotic Knee Surgery System. Computer Aided Surgery. https://doi.org/10.1002/igs.10023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.