Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Optimal orientation of the acetabular component of a total hip prosthesis is an important factor in determining the early and long-term result of a total hip arthroplasty (THA). Conventional positioning of the cup component is usually done using a free-hand method, or with the help of a mechanical acetabular alignment guide. However, these methods have proven to be inaccurate, and a great variation in orientation of the cup is found postoperatively. In this study, we wished to determine if the variability of the abduction angle of acetabular cups could be reduced with the use of computer navigation. The abduction angles of the acetabular components of three groups of 50 THAs were assessed. In the first group, a free-hand method was used to position the cup component. This group was operated in the period before we started using computer navigation for hip surgery. In the second group, CT-based computer navigation was used to plan and help position the cup. The third group consisted of 50 THA cases in which a free-hand method was used to position the cup, although these procedures were performed in the period after we had begun using the Computer Assisted Surgery (CAS) system. The variability in cup abduction angle was assessed in all three groups and compared. There was a significant reduction in variability in the CAS group compared to the first group. There was also a reduction in variability in the CAS group compared to the third group, although this was not statistically significant. It is concluded that the use of computer navigation helped the surgeon to place the cup component with less variability of the abduction angle, and, more importantly, we found that no cups were placed in the more extreme positions (outliers).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Alignment
DiGioia, A. M., Jaramaz, B., Blackwell, M., Simon, D. A., Morgan, F., Moody, J. E., Nikou, C., Colgan, B. D., Aston, C. A., Labarca, R. S., et al. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810000-00003 · Cited by 408
Schmalzried, T. P., Guttmann, D., Grecula, M., & Amstutz, H. C. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199405000-00008 · Cited by 289
Cited by
Pivec, R., Johnson, A. J., Mears, S. C., & Mont, M. A. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60607-2 · Cited by 619
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Metadata
- Authors
- Leenders, T., Vandevelde, D., Mahieu, G., & Nuyts, R.
- Venue
- Computer Aided Surgery
- Publisher
- Informa UK Limited
- Published
- 2002
- Volume
- 7
- Issue
- 2
- Pages
- 99-106
- ISSN
- 1092-9088 (ISSN-L)
- 1097-0150
- OpenAlex
- W2119775410
- Cited by
- 198
- References
- 2
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study. https://app.cochat.ai/papers/10.1002/igs.10033
- The paper
- Leenders, T., Vandevelde, D., Mahieu, G., & Nuyts, R. (2002). Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study. Computer Aided Surgery. https://doi.org/10.1002/igs.10033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.