Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its OpenAlex record.

The application accuracy of the NeuroMate robot?A quantitative comparison with frameless and frame-based surgical localization systems

Qing Hang Li, L. Zamorano, Abhilash D. Pandya, Ramiro Perez, Jianxing Gong, Fernando Diaz · 2002 · Computer Aided Surgery

Abstract

The NeuroMatetrade mark robot system (Integrated Surgical Systems, Davis, CA) is a commercially available, image-guided, robotic-assisted system used for stereotactic procedures in neurosurgery. In this article, we present a quantitative comparison of the application accuracy of the NeuroMate with that of standard frame-based and frameless stereotactic techniques. The article discusses a five-way application accuracy comparison study. The variables of our comparison and their mean errors are as follows: (1) with the robot in a frame-based configuration, the RMS was 0.86 +/- 0.32 mm; (2) with the robot in the frameless configuration, the RMS was 1.95 +/- 0.44 mm; (3) in a standard stereotactic (ZD) frame-based approach, the RMS was 1.17 +/- 0.25 mm; (4) with an infrared tracking system using the frame for fiducial registration, the RMS was 1.47 +/- 0.45 mm; (5) with an infrared tracking system using screw markers for registration, the RMS was 0.68 +/- 0.26 mm. The study was performed with 2-mm sections of CT scans. These results show that the application accuracy of the frame-based NeuroMate robot is comparable to that of standard localizing systems, whether they are frame-based or infrared tracked.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1002/igs.10035

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Li, Q. H., Zamorano, L., Pandya, A. D., Perez, R., Gong, J., & Diaz, F.
Venue
Computer Aided Surgery
Publisher
Taylor & Francis
Published
2002-01-01
Volume
7
Issue
2
Pages
90-98
ISSN
1092-9088 (ISSN-L)
OpenAlex
W2130113954
Cited by
178
References
0
FWCI
11.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.