Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 320

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Fully automatic anatomical, pathological, and functional segmentation from CT scans for hepatic surgery

Open access
Soler, Luc, Delingette, Herve, Malandain, Gregoire, Montagnat, Johan, Ayache, Nicholas, Koehl, Christophe, Dourthe, Olivier, Malassagne, Benoit, Smith, Michelle, Mutter, Didier, Marescaux, Jacques·2001·Computer Aided Surgery

Abstract

OBJECTIVE: To improve the planning of hepatic surgery, we have developed a fully automatic anatomical, pathological, and functional segmentation of the liver derived from a spiral CT scan. MATERIALS AND METHODS: From a 2 mm-thick enhanced spiral CT scan, the first stage automatically delineates skin, bones, lungs, kidneys, and spleen by combining the use of thresholding, mathematical morphology, and distance maps. Next, a reference 3D model is immersed in the image and automatically deformed to the liver contours. Then an automatic Gaussian fitting on the imaging histogram estimates the intensities of parenchyma, vessels, and lesions. This first result is next improved through an original topological and geometrical analysis, providing an automatic delineation of lesions and veins. Finally, a topological and geometrical analysis based on medical knowledge provides hepatic functional information that is invisible in medical imaging: portal vein labeling and hepatic anatomical segmentation according to the Couinaud classification. RESULTS: Clinical validation performed on more than 30 patients shows that delineation of anatomical structures by this method is often more sensitive and more specific than manual delineation by a radiologist. CONCLUSION: This study describes the methodology used to create the automatic segmentation of the liver with delineation of important anatomical, pathological, and functional structures from a routine CT scan. Using the methods proposed in this study, we have confirmed the accuracy and utility of the creation of a 3D liver model compared with the conventional reading of the CT scan by a radiologist. This work may allow improved preoperative planning of hepatic surgery by more precisely delineating liver pathology and its relationship to normal hepatic structures. In the future, this data may be integrated with computer-assisted surgery and thus represents a first step towards the development of an augmented-reality surgical system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/igs.1016

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 320

Metadata

Authors
Soler, L., Delingette, H., Malandain, G., Montagnat, J., Ayache, N., Koehl, C., Dourthe, O., Malassagne, B., Smith, M., Mutter, D., & Marescaux, J.
Venue
Computer Aided Surgery
Published
2001
Volume
6
Issue
3
Pages
131-142
ISSN
  • 1092-9088 (ISSN-L)
  • 1097-0150
OpenAlex
W2084831515
Cited by
320
References
10
FWCI
16.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fully automatic anatomical, pathological, and functional segmentation from CT scans for hepatic surgery. https://app.cochat.ai/papers/10.1002/igs.1016
The paper
Soler, L., Delingette, H., Malandain, G., Montagnat, J., Ayache, N., Koehl, C., Dourthe, O., Malassagne, B., Smith, M., Mutter, D., & Marescaux, J. (2001). Fully automatic anatomical, pathological, and functional segmentation from CT scans for hepatic surgery. Computer Aided Surgery. https://doi.org/10.1002/igs.1016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.