The DOI matches its Crossref record.
Automatic liver segmentation technique for three-dimensional visualization of CT data.
Abstract
PURPOSE: To develop a system for automatic segmentation of the liver from computed tomographic (CT) scans of the abdomen for three-dimensional volume-rendering displays. MATERIALS AND METHODS: An automated liver segmentation system was developed, which combined domain knowledge with analysis of a global histogram, morphologic operators, and the parametrically deformable contour model. Boundaries of the thresholded liver volume were modified section-by-section by exploiting information from adjacent sections. These boundaries were refined by optimization of the parametrically deformable contour model. Volume-rendered images were created by using the boundaries to exclude tissues outside the liver. The system was tested on CT data sets from 10 cases of potentially resectable hepatic neoplasm. RESULTS: Of the 401 sections in the 10 cases, 53 sections (13.2%) required user modifications during segmentation. The utility of the three-dimensional-rendered images with use of these liver boundaries was judged by a radiologist as being comparable to that of three-dimensional images created with manual editing. Twenty-eight of the sections were deemed imperfect by the radiologist and might need further modifications. CONCLUSION: An effective technique for automatic segmentation of the liver from CT images has been developed. This technique promises to save time and simplify the creation of three-dimensional liver images by minimizing operator intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Liver Tumor Segmentation Benchmark (LiTS)
Bilic, P., Christ, P., Li, H. B., Vorontsov, E., Ben-Cohen, A., Kaissis, G., Szeskin, A., Jacobs, C., Mamani, G. E. H., Chartrand, G., et al. (2023) · Medical Image Analysis · doi:10.1016/j.media.2022.102680 · Cited by 1,412
The Liver Tumor Segmentation Benchmark (LiTS)
Bilic, P., Christ, P., Li, H. B., Vorontsov, E., Ben-Cohen, A., Kaissis, G., Szeskin, A., Jacobs, C., Mamani, G. E. H., Chartrand, G., et al. (2019) · arXiv · doi:10.48550/arxiv.1901.04056 · Cited by 1,412
Soler, L., Delingette, H., Malandain, G., Montagnat, J., Ayache, N., Koehl, C., Dourthe, O., Malassagne, B., Smith, M., Mutter, D., et al. (2001) · Computer Aided Surgery · doi:10.1002/igs.1016 · Cited by 320
SEMI-automated liver CT segmentation using Laplacian meshes
Chartrand, G., Cresson, T., Chav, R., Gotra, A., Tang, A., & DeGuise, J. (2014) · 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6867952 · Cited by 32
Metadata
- Authors
- Gao, L., Heath, D. G., Kuszyk, B. S., & Fishman, E. K.
- Venue
- Radiology
- Published
- 1996-11
- Volume
- 201
- Issue
- 2
- Pages
- 359-364
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2155162498
- Cited by
- 177
- References
- 0
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic liver segmentation technique for three-dimensional visualization of CT data. https://app.cochat.ai/papers/10.1148/radiology.201.2.8888223
- The paper
- Gao, L., Heath, D. G., Kuszyk, B. S., & Fishman, E. K. (1996). Automatic liver segmentation technique for three-dimensional visualization of CT data. Radiology. https://doi.org/10.1148/radiology.201.2.8888223
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.