Recent developments in flexible photodetectors based on metal halide perovskite
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Flexible photodetectors (FPDs) have been receiving increasing attention in recent years because of their potential applications in electronic eyes, bioinspired sensing, smart textiles, and wearable devices. Moreover, metal halide perovskites (MHPs) with outstanding optical and electrical properties, good mechanical flexibility, low‐cost and low‐temperature solution‐processed fabrication have become promising candidates as light harvesting materials in FPDs. Herein, we comprehensively review the developments of FPDs based on MHPs reported recently. This review firstly provides an introduction with respect to the performance parameters and device configurations of perovskite photodetectors, followed by the specific requirements of FPDs including substrate and electrode materials. Next, chemical compositions, structures and preparation methods of MHPs are presented. Then, the FPDs on the basis of single‐component perovskite and hybrid structure perovskite are discussed, subsequently, self‐powered flexible perovskite photodetectors were presented. In the end, conclusions and challenges are put forward in the field of FPDs based on perovskites. image
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ambipolar solution-processed hybrid perovskite phototransistors
Li, F., Ma, C., Wang, H., Hu, W., Yu, W., Sheikh, A. D., & Wu, T. (2015) · Nature Communications · doi:10.1038/ncomms9238 · Cited by 629
Deng, W., Zhang, X., Huang, L., Xu, X., Wang, L., Wang, J., Shang, Q., Lee, S., & Jie, J. (2016) · Advanced Materials · doi:10.1002/adma.201505126 · Cited by 432
Photodetectors Based on Organic–Inorganic Hybrid Lead Halide Perovskites
Zhou, J., & Huang, J. (2018) · Advanced Science · doi:10.1002/advs.201700256 · Cited by 307
Self-citation3D Arrays of 1024‐Pixel Image Sensors based on Lead Halide Perovskite Nanowires
Gu, L., Tavakoli, M. M., Zhang, D., Zhang, Q., Waleed, A., Xiao, Y., Tsui, K., Lin, Y., Liao, L., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201601603 · Cited by 300
Deng, W., Huang, H., Jin, H., Li, W., Chu, X., Xiong, D., Yan, W., Chun, F., Xie, M., Luo, C., et al. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801521 · Cited by 210
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Zhao, Y., Yin, X., Li, P., Ren, Z., Gu, Z., Zhang, Y., & Song, Y. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01161-y · Cited by 117
Recent progress of gas sensors based on perovskites
Wei, C., Guo, Z., Wang, H., Zhang, S., Hao, D., & Huang, J. (2025) · Materials Horizons · doi:10.1039/d4mh01306a · Cited by 38
Self-citationQu, M., Guo, Y., Cai, Y., Nie, Z., & Zhang, C. (2024) · Small · doi:10.1002/smll.202310273 · Cited by 14
Metadata
- Authors
- Hao, D., Zou, J., & Huang, J.
- Venue
- InfoMat
- Publisher
- Wiley
- Published
- 2019-11-27
- Volume
- 2
- Issue
- 1
- Pages
- 139-169
- ISSN
- 2567-3165 (ISSN-L)
- OpenAlex
- W2990444490
- Cited by
- 120
- References
- 5
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.