Bone tissue interface
The DOI matches its Crossref record.
Abstract
High resolution microradiography and multiple fluorochrome labeling are definitive histological methods for assessing the mechanism and timing of osseous healing, maturation, and adaptation. Two fundamental types of bone interface have been described for endosseous dental implants: (1) fibro‐osseous integration (“pseudo‐periodontal ligament”) and (2) rigid osseous fixation (“osseointegration”). No definitive bone interface studies with modern physiological methods have been reported for fibro‐osseous integration. Rigid osseous fixation has been investigated in cortical bone implantation sites. The initial healing reaction involves predominantly bone modeling at the periosteal and endosteal surfaces, i.e., a woven bone callus fills with lamellae by the process of lamellar compaction. Nonvital osseous interface and adjacent compacta are replaced by bone remodeling (turnover). As assessed with high resolution microradiography, “clinically successful” specimens had less than half of the intraosseous interface in direct contact with bone. Extrapolation from animal data suggests that endosseous implants can be provisionally loaded at about 18 weeks, but full maturation of the interface requires approximately one year.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Understanding Peri‐Implant Endosseous Healing
Davies, J. E. (2003) · Journal of Dental Education · doi:10.1002/j.0022-0337.2003.67.8.tb03681.x · Cited by 1,063
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
Biomechanical factors affecting the bone-dental implant interface
Brunski, J. B. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90049-y · Cited by 407
A role for surface topography in creating and maintaining bone at titanium endosseous implants
Cooper, L. F. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.111966 · Cited by 336
A new device for absolute anchorage for orthodontics
Block, M. S., & Hoffman, D. R. (1995) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(95)70140-0 · Cited by 313
Cell-Based Bone Tissue Engineering
Meijer, G. J., de Bruijn, J. D., Koole, R., & van Blitterswijk, C. A. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040009 · Cited by 313
Peri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
O'Mahony, A. M., Williams, J. L., & Spencer, P. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120614.x · Cited by 248
Behonick, D. J., Xing, Z., Lieu, S., Buckley, J. M., Lotz, J. C., Marcucio, R. S., Werb, Z., Miclau, T., & Colnot, C. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001150 · Cited by 189
“This spongy bone is eventually remodeled and removed [24,25].”
BackgroundBone modeling: biomechanics, molecular mechanisms, and clinical perspectives
Roberts, W. E., Huja, S., & Roberts, J. A. (2004) · Seminars in Orthodontics · doi:10.1053/j.sodo.2004.01.003 · Cited by 189
Self-citationDhert, W. J. A., Klein, C. P. A. T., Jansen, J. A., van der Velde, E. A., Vriesde, R. C., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270116 · Cited by 179
Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits
Suzuki, K., Aoki, K., & Ohya, K. (1997) · Bone · doi:10.1016/s8756-3282(97)00204-4 · Cited by 169
Metadata
- Authors
- Roberts, W.
- Venue
- Journal of Dental Education
- Publisher
- Wiley
- Published
- 1988-12
- Volume
- 52
- Issue
- 12
- Pages
- 804-809
- ISSN
- 0022-0337 (ISSN-L)
- 1930-7837
- OpenAlex
- W2220534379
- Cited by
- 237
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.