Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 248

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri‐implant stress and strain under oblique loading

O'Mahony, Aisling M., Williams, John L., Spencer, Paulette·2001·Clinical Oral Implants Research

Abstract

Abstract: The aim of this study was to compare implant‐bone interface stresses and peri‐implant principal strains in anisotropic versus isotropic three‐dimensional finite element models of an osseointegrated implant in the posterior mandible. We obtained anisotropic (transversely isotropic) elastic constants for mandibular bone and derived equivalent isotropic constants by averaging over all possible spatial orientations. A finite element model was constructed using ten‐node tetrahedral p‐elements, providing curved edges where necessary and increasing the accuracy of the results in regions of high stress gradients. Perfect bonding was assumed at the implant‐bone interface. An oblique load was applied at the coronal aspect of the crown with 100 N vertical and 20 N bucco‐to‐lingual components. Implant‐bone interface stresses exceeded reported bond strengths and principal strains reached yield strain levels in the cortical crest. Anisotropy increased what were already high levels of stress and strain in the isotropic case by 20 to 30% in the cortical crest. In cancellous bone, anisotropy increased what were relatively low levels of interface stress in the isotropic case by three‐ to four‐fold to exceed bond strength levels. Anisotropy has subtle, yet significant effects on interface stresses and peri‐implant strains and careful consideration should be given to its use in finite element studies of dental implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2001.120614.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 248

Metadata

Authors
O'Mahony, A. M., Williams, J. L., & Spencer, P.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2001-12
Volume
12
Issue
6
Pages
648-657
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2006822529
Cited by
248
References
1
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri‐implant stress and strain under oblique loading. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.120614.x
The paper
O'Mahony, A. M., Williams, J. L., & Spencer, P. (2001). Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri‐implant stress and strain under oblique loading. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.120614.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.