The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Confocal Multimode Resonator for Millimeter Through Optical Wavelength Masers
Abstract
Multimode resonators of high quality factor will very likely play a significant role in the development of devices, such as the maser, which operate in the millimeter through optical wavelength range. It has been suggested that a plane-parallel Fabry-Perot interferometer could act as a suitable resonator. In this paper a resonator consisting of two identical concave spherical reflectors, separated by any distance up to twice their common radius of curvature, is considered. Mode patterns and diffraction losses for the low-loss modes of such a resonator are obtained analytically, using an approximate method which was suggested by W. D. Lewis. The results show that the diffraction losses are generally considerably lower for the curved surfaces than for the plane surfaces. Diffraction losses and mode volume are a minimum when the reflector spacing equals the common radius of curvature of the reflectors. For this case the resonator may be termed confocal. A further property of the concave spherical resonator is that the optical alignment is not extremely critical.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prolate Spheroidal Wave Functions, Fourier Analysis and Uncertainty - I
Slepian, D., & Pollak, H. O. (1961) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1961.tb03976.x · Cited by 2,492
Cited by
Hollow Metallic and Dielectric Waveguides for Long Distance Optical Transmission and Lasers
Marcatili, E. A. J., & Schmeltzer, R. A. (1964) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1964.tb04108.x · Cited by 1,381
Off-Axis Paths in Spherical Mirror Interferometers
Herriott, D., Kogelnik, H., & Kompfner, R. (1964) · Applied Optics · doi:10.1364/ao.3.000523 · Cited by 869
Kogelnik, H. (1965) · Applied Optics · doi:10.1364/ao.4.001562 · Cited by 560
Noncommutative Geometry, Quantum Fields and Motives
Connes, A., & Marcolli, M. (2007) · Colloquium Publications · doi:10.1090/coll/055 · Cited by 368
Theory of the Prism–Film Coupler by Plane-Wave Analysis
Ulrich, R. (1970) · Journal of the Optical Society of America · doi:10.1364/josa.60.001337 · Cited by 356
Metadata
- Authors
- Boyd, G. D., & Gordon, J. P.
- Venue
- Bell System Technical Journal
- Published
- 1961-03
- Volume
- 40
- Issue
- 2
- Pages
- 489-508
- ISSN
- 0005-8580 (ISSN-L)
- OpenAlex
- W2098682104
- Cited by
- 883
- References
- 1
- FWCI
- 96.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Confocal Multimode Resonator for Millimeter Through Optical Wavelength Masers. https://app.cochat.ai/papers/10.1002/j.1538-7305.1961.tb01626.x
- The paper
- Boyd, G. D., & Gordon, J. P. (1961). Confocal Multimode Resonator for Millimeter Through Optical Wavelength Masers. Bell System Technical Journal. https://doi.org/10.1002/j.1538-7305.1961.tb01626.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.