The DOI matches its OpenAlex record.
Importance of the Lipid Layer in Human Tear Film Stability and Evaporation
Abstract
PURPOSE: Previous work on rabbits has demonstrated a four-fold increase in tear evaporation when the tear lipid layer is removed. However, in vitro work has suggested that the lipid layer does not play a role in retarding evaporation of the aqueous layer. The importance of the lipid layer in human tear film stability and evaporation was determined in the current study by measurement of these parameters in the same individuals. METHODS: The left eyes of 161 normal and dry eye subjects (72 males, 89 females), with an age range of 13 to 85 years, were examined. Tear evaporation was derived from the vapor pressure gradient measured with a modified Servomed evaporimeter. Lipid layer structure and noninvasive break-up time (NIBUT) were assessed clinically, by specular reflection, with the Keeler Tearscope. Lipid layer structure was categorized into marmoreal (open and closed meshwork), flow, amorphous, and colored fringe (normal and abnormal) patterns. These observed patterns reflect lipid layer thickness. Ambient temperature and relative humidity remained fairly constant throughout the experiment. RESULTS: Tear evaporation rate was found to vary significantly with different lipid layer patterns. Eyes with no visible lipid layer, or exhibiting an abnormal colored fringe pattern (with clumping of lipid amidst areas of little or no lipid cover), demonstrated a significantly higher rate of evaporation of the tear film (p < 0.001). There were no significant differences amongst the remainder of the patterns. The NIBUT was also found to vary significantly with lipid layer pattern (p < 0.001), with the absent or abnormal colored fringe lipid patterns exhibiting the poorest stability. CONCLUSIONS: Where the human lipid layer is absent, or is not confluent, and the tear film is unstable, tear evaporation is increased four-fold. However, where there is a stable, intact lipid layer, regardless of lipid thickness, tear evaporation is retarded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70081-2 · Cited by 3,267
TFOS DEWS II Diagnostic Methodology report
Wolffsohn, J. S., Arita, R., Chalmers, R., Djalilian, A., Dogru, M., Dumbleton, K., Gupta, P. K., Karpecki, P., Lazreg, S., Pult, H., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.001 · Cited by 2,122
Self-citationThe thickness of the tear film
King-Smith, E., Fink, B., Hill, R., Koelling, K., & Tiffany, J. (2004) · Current Eye Research · doi:10.1080/02713680490516099 · Cited by 307
Smolyanskaya, O. A., Chernomyrdin, N. V., Konovko, A. A., Zaytsev, K. I., Ozheredov, I. A., Cherkasova, O. P., Nazarov, M. M., Guillet, J.-P., Kozlov, S. A., Kistenev, Y. V., et al. (2018) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2018.10.001 · Cited by 292
Dry Eye Management: Targeting the Ocular Surface Microenvironment
Zhang, X., M, V. J., Qu, Y., He, X., Ou, S., Bu, J., Jia, C., Wang, J., Wu, H., Liu, Z., et al. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18071398 · Cited by 267
Metadata
- Authors
- Craig, J. P., & Tomlinson, A.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 1997-01-01
- Volume
- 74
- Issue
- 1
- Pages
- 8-13
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2019467202
- Cited by
- 445
- References
- 0
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Importance of the Lipid Layer in Human Tear Film Stability and Evaporation. https://app.cochat.ai/papers/10.1002/j.1538-9235.1997.tb04573.x
- The paper
- Craig, J. P., & Tomlinson, A. (1997). Importance of the Lipid Layer in Human Tear Film Stability and Evaporation. Optometry and Vision Science. https://doi.org/10.1002/j.1538-9235.1997.tb04573.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.