CoChat

Impact of Various Body Weights and Serum Creatinine Concentrations on the Bias and Accuracy of the Cockcroft‐Gault Equation

Winter, Mary A., Guhr, Kelly N., Berg, Gina M. · 2012 · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
Cited by 189

The DOI matches its Crossref record.

Abstract

Study Objective: To evaluate the impact of various body weights and serum creatinine (S cr) concentrations on the bias and accuracy of the C ockcroft‐G ault creatinine clearance (C‐G C lcr) equation compared with measured 24‐hour C lcr. Design: Retrospective analysis. Setting: Tertiary care hospital. Patients: A total of 3678 patients with stable renal function and who underwent a 24‐hour urine collection between J uly 1, 1996, and J une 30, 2010. Measurements and Main Results: For each patient, C‐G C lcr was calculated and compared with a measured 24‐hour C lcr. Body weight adjustments to the calculation were performed based on the following weight classifications: underweight, normal weight, overweight, obese, and morbidly obese. In addition, C‐G C lcr was calculated by using rounded S cr values based on two S cr thresholds—0.8 mg/dl and 1 mg/dl—for patients with measured S cr values below those thresholds. Those patients were then evaluated after stratification into two age groups: all ages and a subgroup of patients aged 65 years or older. The S cr‐rounded C‐G C lcr values were compared with the C‐G C lcr values using actual S cr values. Mean differences were calculated, and accuracy was evaluated. Use of actual body weight in the calculations for underweight patients resulted in an unbiased C lcr of −0.22 ml/minute (p=0.898). Use of ideal body weight in the calculations of patients of normal weight returned an unbiased C lcr of −1.3 ml/minute (p=0.544). An unbiased C‐G C lcr could not be calculated for other weight categories. In those patients, adjusted body weight using a factor of 0.4 (ABW0.4) was the least biased and most accurate. In patients aged 65 years or older with an S cr less than 0.8 mg/dl and less than 1 mg/dl, actual S cr was unbiased (−3 ml/min [p=1] and −9 ml/min [p=0.279], respectively) and more accurate than rounded S cr. In patients of all ages with an S cr less than 0.8 mg/dl and less than 1 mg/dl, actual S cr proved less biased (−4.5 ml/min [p=0.038] and −5.5 ml/min [p<0.001], respectively) and more accurate than rounded S cr. Conclusion: An unbiased C‐G C lcr can be calculated using actual body weight in underweight patients and ideal body weight in patients of normal weight. Using ABW0.4 for overweight, obese, and morbidly obese patients appears to be the least biased and most accurate method for calculating their C‐G C lcr. Rounding S cr in patients with low S cr did not improve accuracy or bias of the Cl cr calculations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/j.1875-9114.2012.01098.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Winter, M. A., Guhr, K. N., & Berg, G. M.
Venue
Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
Publisher
Wiley
Published
2012-05-10
Volume
32
Issue
7
Pages
604-612
ISSN
  • 0277-0008 (ISSN-L)
  • 1875-9114
OpenAlex
W2030833828
Cited by
189
References
0
FWCI
6.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Various Body Weights and Serum Creatinine Concentrations on the Bias and Accuracy of the Cockcroft‐Gault Equation. https://app.cochat.ai/papers/10.1002/j.1875-9114.2012.01098.x
The paper
Winter, M. A., Guhr, K. N., & Berg, G. M. (2012). Impact of Various Body Weights and Serum Creatinine Concentrations on the Bias and Accuracy of the Cockcroft‐Gault Equation. Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy. https://doi.org/10.1002/j.1875-9114.2012.01098.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.