Quality Control During the Conventional Analysis of Semen, An Essential Exercise
The DOI matches its Crossref record.
Abstract
Intra‐ and inter‐technician variability in assessing sperm motility by the methods recently advocated by the World Health Organization (WHO) were studied. The intra‐ and inter‐technician variability in estimating sperm concentration and the intra‐technician variability in assessing sperm morphology were also examined. Intra‐technician variability in assessing sperm motility appeared to be related to the natural ability and/or training of the observer. Although in general the intra‐technician variability was low, there were marked and clinically significant differences between observers when assessing the same semen sample. There was no significant difference between observers in the assessment of sperm concentration, and intra‐technician variability was low. When assessing sperm morphology, the intra‐technician variability was potentially large (above a level of 20% morphologically ideal spermatozoa). Technicians should be recruited who have natural ability as observers. Quality control appears to be an essential exercise for any center that plans to relate semen parameters to fertility outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kessopoulou, E., Powers, H. J., Sharma, K. K., Pearson, M. J., Russell, J. M., Cooke, I. D., & Barratt, C. L. R. (1995) · Fertility and Sterility · doi:10.1016/s0015-0282(16)57861-3 · Cited by 335
Self-citationSmoking and male reproduction: a review
VINE, M. F. (1996) · International Journal of Andrology · doi:10.1111/j.1365-2605.1996.tb00523.x · Cited by 270
External quality control in the andrology laboratory: an experimental multicenter trial
Neuwinger, J., Behre, H. M., & Nieschlag, E. (1990) · Fertility and Sterility · doi:10.1016/s0015-0282(16)53709-1 · Cited by 227
Auger, J. (2000) · Human Reproduction · doi:10.1093/humrep/15.11.2360 · Cited by 191
“However, better reproducibility in the assessment of sperm motility could also depend on the natural ability of the observer for this subjective task, as was suggested in an earlier study (Dunphy et al., 1989).”
MethodResultInfluentialInternal quality control of semen analysis
Cooper, T. G., Neuwinger, J., Bahrs, S., & Nieschlag, E. (1992) · Fertility and Sterility · doi:10.1016/s0015-0282(16)55156-5 · Cited by 164
Metadata
- Authors
- DUNPHY, B. C., KAY, R., BARRATT, C. L. R., & COOKE, I. D.
- Venue
- Journal of Andrology
- Publisher
- Wiley
- Published
- 1989-09-10
- Volume
- 10
- Issue
- 5
- Pages
- 378-385
- ISSN
- 0196-3635 (ISSN-L)
- 1939-4640
- OpenAlex
- W1485824897
- Cited by
- 106
- References
- 0
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality Control During the Conventional Analysis of Semen, An Essential Exercise. https://app.cochat.ai/papers/10.1002/j.1939-4640.1989.tb00124.x
- The paper
- DUNPHY, B. C., KAY, R., BARRATT, C. L. R., & COOKE, I. D. (1989). Quality Control During the Conventional Analysis of Semen, An Essential Exercise. Journal of Andrology. https://doi.org/10.1002/j.1939-4640.1989.tb00124.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.