The DOI matches its Crossref record.
Acute toxicity of metal ions in cultures of osteogenic cells derived from bone marrow stromal cells
Abstract
The effects of metal ions released from orthopedic implants on nearby bone cells remain largely unknown. The purpose of this study was to examine the acute toxicity of metal ions on osteogenic cells derived from bone marrow. Bone marrow stromalcells were cultured with metal ions found in commonly used orthopedic implants, that is, Ti‐6Al‐4V, Co‐Cr‐Mo, and 316L stainless steel. Solutions of individual ions and combinations representing the alloy composition were prepared from atomic absorption standards and added to the cultures to give concentrations ranging from 50 ppb to 5o ppm. After a 48‐h period of exposure to ions, the bone marrow cultures were examined for effects of cytotoxicity by measuring total cell number, total cell protein, and mitochondrial activity. Cr 6+was grossly cytotoxic; Co 2+, Mo 6+, Fe 3+, and Ni 2+were moderately cytotoxic; and Ti 4+, Al 3+, V 5+, and Mn 2+were minimally toxic, as determined by the assays used. Ion solutions representing Co‐Cr‐Mo and 316L stainless steel were moderately toxic; solutions representing Ti‐6Al‐4V were toxic at only the highest concentrations used. The observed cytotoxicity was time‐dependent, with irreversible toxic effects being initiated following as short as a 3‐ to 6‐hour exposure. These results show that metal ions associated with Co‐Cr‐Mo and 316L stainless steel are toxic to osteogenic cells at concentrations approximating those measured in the fibrous membrane encapsulating orthopedic implants. © 1995 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
In vivo study of magnesium plate and screw degradation and bone fracture healing
Chaya, A., Yoshizawa, S., Verdelis, K., Myers, N., Costello, B. J., Chou, D.-T., Pal, S., Maiti, S., Kumta, P. N., & Sfeir, C. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.02.010 · Cited by 359
Tite, T., Popa, A.-C., Balescu, L. M., Bogdan, I. M., Pasuk, I., Ferreira, J. M. F., & Stan, G. E. (2018) · Materials · doi:10.3390/ma11112081 · Cited by 282
Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts
Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10106 · Cited by 280
B iocompatibility of D ental C asting A lloys
Geurtsen, W. (2002) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130201300108 · Cited by 221
Metadata
- Authors
- Puleo, D. A., & Huh, W. W.
- Venue
- Journal of Applied Biomaterials
- Publisher
- Wiley
- Published
- 1995-06
- Volume
- 6
- Issue
- 2
- Pages
- 109-116
- ISSN
- 1045-4861 (ISSN-L)
- 1549-9316
- OpenAlex
- W2140129846
- Cited by
- 193
- References
- 0
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute toxicity of metal ions in cultures of osteogenic cells derived from bone marrow stromal cells. https://app.cochat.ai/papers/10.1002/jab.770060205
- The paper
- Puleo, D. A., & Huh, W. W. (1995). Acute toxicity of metal ions in cultures of osteogenic cells derived from bone marrow stromal cells. Journal of Applied Biomaterials. https://doi.org/10.1002/jab.770060205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.