The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts
Abstract
Metal debris from implants has been shown to alter the function of osteoblasts in cell cultures. Its remains unclear, however, if specific forms of released ionic metals are involved in the pathogenesis of periprosthetic osteolysis. We evaluated the relative effects of ionic forms of implant metals by treating human osteoblast‐like MG‐63 osteosarcoma cells with eight concentrations (0.001–10.0 m M) of Cr+3, Mo+5, Al+3, Ta+5, Co+2, Ni+2, Fe+3, Cu+2, Mn+2, Mg+2, Na+2, and V+3 chloride solutions. The results demonstrated that the metal ions differentially affected osteoblast proliferation, viability, type‐I collagen gene expression, and cytokine release. The metal ions were ranked in order from least to most toxic (based on a 50% reduction in viability) as follows: Na < Cr < Mg < Mo < Al < Ta < Co < Ni < Fe < Cu < Mn < V. Metal‐induced decreases in osteoblast proliferation were similar in ranking. Nontoxic concentrations of metals had no effect on procollagen α1[I] gene expression; only at toxic concentrations did metals produce a decrease in gene expression. The most toxic metals (V, Mn, Fe, and Ni) were also the only metals found to induce IL‐6 secretion on a per cell basis (of the cytokines tested, interleukin 6 (IL‐6), interleukin beta 1 (IL‐1β), transforming growth factor beta 1 (TGF‐β1), and tumor necrosis factor alpha (TNF‐α), only IL‐6 was detectable in the culture medium after 48 h for any metal at any concentration). Less toxic metals (e.g., Co and Cr) had little effect on IL‐6 release, even at high concentrations. In general, metal ions reduced osteoblast function (i.e., proliferation and collagen gene expression) in proportion to the degree of toxicity. These results support the hypothesis that adverse local cellular responses (particularly necrotic responses) associated with metal debris from implanted metallic devices may be due in part to metal ions released from implants or from particulate debris. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 420–433, 2002; DOI 10.1002/jbm.10106
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction
Chomczynski, P., & Sacchi, N. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90021-2 · Cited by 46,426
Schmalzried, T. P., Jasty, M., & Harris, W. H. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274060-00006 · Cited by 989
Corrosion of Metal Orthopaedic Implants*
Jacobs, J. J., Gilbert, J. L., & Urban, R. M. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199802000-00015 · Cited by 967
Self-citationURBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
Self-citationBanaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_20 · Cited by 783
Basic and Clinical Immunology.
(1979) · Annals of Internal Medicine · doi:10.7326/0003-4819-90-4-732_3 · Cited by 767
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Self-citationUrban, R. M., Jacobs, J. J., Gilbert, J. L., & Galante, J. O. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199409000-00009 · Cited by 337
Self-citationBone resorption activity of particulate-stimulated macrophages
Glant, T. T., Jacobs, J. J., Molnár, G., Shanbhag, A. S., Valyon, M., & Galante, J. O. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080907 · Cited by 309
Self-citationJasty, M., Goetz, D. D., Bragdon, C. R., et al. (1997) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199703000-00005 · Cited by 257
Cited by
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Yoshizawa, S., Brown, A., Barchowsky, A., & Sfeir, C. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.002 · Cited by 577
Corrosion resistance and surface biocompatibility of a microarc oxidation coating on a Mg–Ca alloy
Gu, X. N., Li, N., Zhou, W. R., Zheng, Y. F., Zhao, X., Cai, Q. Z., & Ruan, L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.034 · Cited by 383
The effects on bone cells of metal ions released from orthopaedic implants. A review
Sansone, V (2013) · CLINICAL CASES IN MINERAL AND BONE METABOLISM · doi:10.11138/ccmbm/2013.10.1.034 · Cited by 289
Novel processing of iron–manganese alloy-based biomaterials by inkjet 3-D printing
Chou, D.-T., Wells, D., Hong, D., Lee, B., Kuhn, H., & Kumta, P. N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.04.016 · Cited by 259
Metadata
- Authors
- Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-02-21
- Volume
- 60
- Issue
- 3
- Pages
- 420-433
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1991267506
- Cited by
- 280
- References
- 29
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts. https://app.cochat.ai/papers/10.1002/jbm.10106
- The paper
- Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J. (2002). Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.