CoChat

Validation of an improved nose-only exposure system for rodents

Pauluhn, J. · 1994 · Journal of Applied Toxicology

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Several types and modifications of nose-only inhalation chambers for exposing rodents are described. The improvement of this 'flow-past' -like nose-only exposure system is that it is modular, i.e. it can be used for acute studies with a maximum of 20 rodents (one segment) or for chronic inhalation studies with 100 (or more) rodents per chamber with five (or more) segments. Another goal was to design a nose-only exposure system that provides maximal computer support and automatization, as well as robust aerosol collection conditions. The evaluation of the five-segment chamber, charged with 98 rats, revealed that a flow rate of 0.75 l air min-1 or approximately 2.5 times the rat minute ventilation volume per exposure port is sufficient to provide homogeneous temporal and spatial exposure conditions. Also, the aerosol size distribution was constant throughout the chamber. Experimental data suggest that computer-controlled sampling of the test atmosphere up to ca. 6 l air min-1 did not alter the flow dynamics of the exposure system. The nose-only inhalation chamber developed is suitable for short-term and long-term inhalation toxicity studies using small laboratory rodents with minimal consumption of test compound.

Overview

Integrity signals

Registry

Crossref · 10.1002/jat.2550140111

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 8

  1. R. F.Phalen M. T.Kleinman W. J.MautzandR. T.Drew Inhalation exposure methodology.IPCS/German/ILSI/ IUTOX International Symposium on Respiratory Toxicology and Risk Assessment Hanover Germany 6–9 October1992.
  2. Pauluhn J., 1984, Problems of Inhalatory Toxicity Studies, 59
  3. EC‐Guideline 86/609, 1986, Guidelines concerning the protection of animals used for studies and other scientific purposes, Journal of the European Community – Legal Specifications L, 358, 29
  4. Pauluhn J., 1988, Inhalation Toxicology — The Design and Interpretation of Inhalation Studies and Their Use in Risk Assessment, 87
  5. McFarland H. N., 1976, Respiratory Toxicology — Essays in Toxicology, 121
  6. Raabe O. G., 1982, Mechanisms in Respiratory Toxicology, 27
  7. Raabe O. G., 1970, Inhalation Carcinogenesis, 123
  8. The United States Pharmacopeia 22nd ed. (601) Aerosols/Physical Tests and Determinations USP XXXII Suppl. 7 NF XVII pp.3122–3129 released September 15 1992.

Cited by

See all 65

Metadata

Authors
Pauluhn, J.
Affiliations
Bayer (Germany) (DE)
Corresponding author
Pauluhn, J.
Venue
Journal of Applied Toxicology
Publisher
Wiley
Published
1994-01
Volume
14
Issue
1
Pages
55-62
ISSN
  • 0260-437X (ISSN-L)
  • 1099-1263
OpenAlex
W2022508295
Cited by
65
References
18
Citations by year
2023: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 3 · 2012: 2
FWCI
2.07
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Toxicology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
  • Life Sciences › Immunology and Microbiology › Immunology › Immunotoxicology and immune responses
  • Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
Keywords
aerosol collection, aerosol size distribution, air flow rate, inhalation toxicity testing, rats
MeSH terms
Administration, Inhalation, Aerosols, Air, Animals, Atmosphere Exposure Chambers, Computers, Humidity, Insecticides, Nitriles, Nose, Particle Size, Pyrethrins, Temperature, Rats, Wistar, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.