Validation of an improved nose-only exposure system for rodents
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Several types and modifications of nose-only inhalation chambers for exposing rodents are described. The improvement of this 'flow-past' -like nose-only exposure system is that it is modular, i.e. it can be used for acute studies with a maximum of 20 rodents (one segment) or for chronic inhalation studies with 100 (or more) rodents per chamber with five (or more) segments. Another goal was to design a nose-only exposure system that provides maximal computer support and automatization, as well as robust aerosol collection conditions. The evaluation of the five-segment chamber, charged with 98 rats, revealed that a flow rate of 0.75 l air min-1 or approximately 2.5 times the rat minute ventilation volume per exposure port is sufficient to provide homogeneous temporal and spatial exposure conditions. Also, the aerosol size distribution was constant throughout the chamber. Experimental data suggest that computer-controlled sampling of the test atmosphere up to ca. 6 l air min-1 did not alter the flow dynamics of the exposure system. The nose-only inhalation chamber developed is suitable for short-term and long-term inhalation toxicity studies using small laboratory rodents with minimal consumption of test compound.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Humidity fixed points of binary saturated aqueous solutions
Greenspan, L. (1977) · Journal of Research of the National Bureau of Standards Section A: Physics and Chemistry · doi:10.6028/jres.081a.011 · Cited by 4,001
Inhalation Studies: Foundations and Techniques
Kutzman, R. S. (1984) · Environmental Health Perspectives · doi:10.1289/ehp.58-1569427 · Cited by 228
The Flow-Past Chamber: An Improved Nose-Only Exposure System for Rodents
CANNON, W. C., BLANTON, E. F., & McDONALD, K. E. (1983) · American Industrial Hygiene Association Journal · doi:10.1080/15298668391405959 · Cited by 162
Aerosols in the mining and industrial work environments
Marple, V. A., Liu, B., & Environment, I. W. (1983) · Medical Entomology and Zoology · Cited by 156
Long-Term Retention and Clearance of Particles Inhaled by Mammalian Species
Snipes, M. B. (1989) · Critical Reviews in Toxicology · doi:10.3109/10408448909017909 · Cited by 154
Concepts in inhalation toxicology
Kehrer, J. P. (1989) · Toxicology Letters · doi:10.1016/0378-4274(89)90176-8 · Cited by 120
Respiration of F344 rats in nose‐only inhalation exposure tubes
Mauderly, J. L. (1986) · Journal of Applied Toxicology · doi:10.1002/jat.2550060106 · Cited by 107
Rosiello, A. P., Essigmann, J. M., & Wogan, G. N. (1977) · Journal of Toxicology and Environmental Health · doi:10.1080/15287397709529614 · Cited by 68
Inhalation Exposure Methodology
Phalen, R. F., Mannix, R. C., & Drew, R. T. (1984) · Environmental Health Perspectives · doi:10.1289/ehp.845623 · Cited by 68
Generation of aerosols and facilities for exposure experiments
Benarie, M. M. (1981) · The Science of The Total Environment · doi:10.1016/0048-9697(81)90010-3 · Cited by 66
Research works printed but not linked: 8
- R. F.Phalen M. T.Kleinman W. J.MautzandR. T.Drew Inhalation exposure methodology.IPCS/German/ILSI/ IUTOX International Symposium on Respiratory Toxicology and Risk Assessment Hanover Germany 6–9 October1992.
- Pauluhn J., 1984, Problems of Inhalatory Toxicity Studies, 59
- EC‐Guideline 86/609, 1986, Guidelines concerning the protection of animals used for studies and other scientific purposes, Journal of the European Community – Legal Specifications L, 358, 29
- Pauluhn J., 1988, Inhalation Toxicology — The Design and Interpretation of Inhalation Studies and Their Use in Risk Assessment, 87
- McFarland H. N., 1976, Respiratory Toxicology — Essays in Toxicology, 121
- Raabe O. G., 1982, Mechanisms in Respiratory Toxicology, 27
- Raabe O. G., 1970, Inhalation Carcinogenesis, 123
- The United States Pharmacopeia 22nd ed. (601) Aerosols/Physical Tests and Determinations USP XXXII Suppl. 7 NF XVII pp.3122–3129 released September 15 1992.
Cited by
Pauluhn, J. (2010) · Toxicological Sciences · doi:10.1093/toxsci/kfp247 · Cited by 358
Nahar, K., Gupta, N., Gauvin, R., Absar, S., Patel, B., Gupta, V., Khademhosseini, A., & Ahsan, F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.06.004 · Cited by 168
“, 2013) and large number of animals (Pauluhn, 1994).”
Inhalation exposure systems: design, methods and operation
Wong, B. A. (2007) · Toxicologic Pathology · doi:10.1080/01926230601060017 · Cited by 137
Toxicity, phototoxicity and biocidal activity of nanoparticles employed in photocatalysis
Friehs, E., AlSalka, Y., Jonczyk, R., Lavrentieva, A. V., Jochums, A., Walter, J., Stahl, F., Scheper, T. H., & Bahnemann, D. W. (2016) · Journal of Photochemistry and Photobiology C Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2016.09.001 · Cited by 150
Ellinger-Ziegelbauer, H. C., & Pauluhn, J. (2009) · Toxicology · doi:10.1016/j.tox.2009.10.007 · Cited by 114
Pauluhn, J. (2009) · Toxicological Sciences · doi:10.1093/toxsci/kfp046 · Cited by 103
“Details of this modular chamber and its validation have been published in detail elsewhere (Pauluhn, 1994; Pauluhn and Thiel, 2007).”
Respiratory sensitization and allergy: Current research approaches and needs
Boverhof, D. R., Billington, R., Gollapudi, B. B., Hotchkiss, J. A., Krieger, S. M., Poole, A., Wiescinski, C. M., & Woolhiser, M. R. (2007) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2007.10.008 · Cited by 102
“…volume, peak expiratory flow, inspiratory and expiratory times and a flow-derived estimation of airflow restriction (enhanced pause, Penh) are often used for quantitative assessment of allergen induced airway hyperreactivity (Thorne and Karol, 1988; Pauluhn, 1994, 1997; Pauluhn and Mohr, 1994).”
MethodLinnarsson, D., Carpenter, J., Fubini, B., Gerde, P., Karlsson, L. L., Loftus, D. J., Prisk, G. K., Staufer, U., Tranfield, E. M., & van Westrenen, W. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.05.023 · Cited by 95
“For diseases such as lung 600 cancer or airway remodelling driven by chronic inflammation, most studies have been 601 done with mice or rats either in whole-body chambers (Heinrich et al., 1995) or in 602 nose-only exposure towers (Pauluhn, 1994, 2008; Wong, 2007).”
BackgroundReview Article: Inhalation Studies in Laboratory Animals—Current Concepts and Alternatives
Pauluhn, J., & Möhr, U. (2000) · Toxicologic Pathology · doi:10.1177/019262330002800514 · Cited by 90
“The respective directed-flow nose-only inhalation chamber, modular in design to allow exposure of a variable number of rodents, is shown in Figure 8 (62).”
BackgroundKaur, J. P., Muttil, P., Verma, R. K., Kumar, K., Yadav, A. B., Sharma, R., & Misra, A. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.02.008 · Cited by 77
“air pressure, aerosol concentration, etc. [ 12 , 13].”
Experimental approaches to evaluate respiratory allergy in animal models
Pauluhn, J., & Möhr, U. (2005) · Experimental and Toxicologic Pathology · doi:10.1016/j.etp.2004.10.002 · Cited by 72
Liu, F., Li, W., Pauluhn, J., Trübel, H., & Wang, C. (2013) · Toxicology · doi:10.1016/j.tox.2012.12.020 · Cited by 66
A simple approach to validation of directed‐flow nose‐only inhalation chambers
Pauluhn, J., & Thiel, A. (2007) · Journal of Applied Toxicology · doi:10.1002/jat.1188 · Cited by 64
“…have advantages over mixed-flow nose-only systems as the rebreathing of test atmospheres is minimized or even excluded and that similar exposure conditions prevail at each exposure location (Ayres et al., 1990; Cannon et al., 1983; Cheng and Moss, 1995; Moss et al., 2006; Pauluhn, 1994).”
BackgroundMethodInfluentialPauluhn, J. (2004) · Toxicological Sciences · doi:10.1093/toxsci/kfh187 · Cited by 68
“75 l/min/exposureport.Detailsof thenose-onlyexposure system used have been published elsewhere (Pauluhn, 1994).”
MethodNadithe, V., Rahamatalla, M., Finlay, W. H., Mercer, J. R., & Samuel, J. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10379 · Cited by 63
Pauluhn, J. (2006) · Inhalation Toxicology · doi:10.1080/08958370600563680 · Cited by 52
“Details of this modular chamber and its validation with regard to spatial homogeneity have been published elsewhere (Pauluhn, 1994).”
BackgroundOverview of inhalation exposure techniques: Strengths and weaknesses
Pauluhn, J. (2005) · Experimental and Toxicologic Pathology · doi:10.1016/j.etp.2005.05.014 · Cited by 52
Pauluhn, J. (2000) · Toxicological Sciences · doi:10.1093/toxsci/58.1.173 · Cited by 49
“The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD) were calculated as described previously (Pauluhn, 1994).”
MethodSelg, E., Ewing, P., Acevedo, F., Sjöberg, C.-O., Ryrfeldt, Å., & Gerde, P. (2012) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2012.0971 · Cited by 42
Pauluhn, J., & Möhr, U. (1994) · Toxicology · doi:10.1016/0300-483x(94)90167-8 · Cited by 39
Pauluhn, J. (2002) · Inhalation Toxicology · doi:10.1080/08958370252809068 · Cited by 39
“The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD) were calculated as described previously (Pauluhn, 1994).”
MethodA Small Whole-Body Exposure Chamber for Laboratory Use
O’Shaughnessy, P. T., Achutan, C., O'Neill, M. E., & Thorne, P. S. (2003) · Inhalation Toxicology · doi:10.1080/08958370304504 · Cited by 35
“The nose-only chamber is a useful alternative to the large, whole-body chamber (Cannon et al., 1983; Pauluhn, 1994).”
BackgroundPauluhn, J., Eidmann, P., Freyberger, A., Kempka, G., & Vohr, H.-W. (2002) · Journal of Applied Toxicology · doi:10.1002/jat.831 · Cited by 34
“The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD) were calculated as described previously.(26) Values of the mean MMAD were 3.”
MethodPauluhn, J. (2004) · Inhalation Toxicology · doi:10.1080/08958370490434060 · Cited by 33
“The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD) were calculated as described previously (Pauluhn, 1994).”
MethodPauluhn, J. (1997) · Fundamental and Applied Toxicology · doi:10.1006/faat.1997.2393 · Cited by 32
“lished validation data indicated that this inhalation system provides a high degree of spatial and temporal uniformity of test atmosphere ( Pauluhn, 1994d ).”
BackgroundPauluhn, M. E. J. (1999) · Inhalation Toxicology · doi:10.1080/089583799196637 · Cited by 31
Pauluhn, J. (2000) · Toxicological Sciences · doi:10.1093/toxsci/56.1.105 · Cited by 30
Pauluhn, J., Hahn, A., & Spielmann, H. (2008) · Inhalation Toxicology · doi:10.1080/08958370802220634 · Cited by 28
“The median aerodynamic diameter (MMAD) and geometric standard deviation (GSD) were calculated as described in detail elsewhere (Pauluhn, 1994; Pauluhn, 2005a; USP XXII, 1992).”
MethodRisk assessment of pyrethroids following indoor use
Pauluhn, J. (1996) · Toxicology Letters · doi:10.1016/0378-4274(96)03759-9 · Cited by 26
Pauluhn, J. (2013) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2013.05.008 · Cited by 26
“This study attempts to reconcile this controversy in using a rigorously validated directed-flow nose-only exposure system (Pauluhn, 1994; Pauluhn and Thiel, 2007) equipped with real-time analytical procedures (FTIR) and physical atmosphere characterization (humidity, temperature) to overcome the shortcomings of past s…”
MethodPauluhn, J. (2005) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2005.04.007 · Cited by 25
Pauluhn, J. (1999) · Inhalation Toxicology · doi:10.1080/089583799197140 · Cited by 25
Mosquito coil smoke inhalation toxicity. Part II: Subchronic nose‐only inhalation study in rats
Pauluhn, J., & Möhr, U. (2006) · Journal of Applied Toxicology · doi:10.1002/jat.1139 · Cited by 22
“The pressure difference between the inner inhalation chamber and the exposure zone was 0.02 cm H2O (Pauluhn, 1994).”
BackgroundInfluentialAssessment of pyrethroid-induced paraesthesias: comparison of animal model and human data
Pauluhn, J. (1998) · Toxicology Letters · doi:10.1016/s0378-4274(98)00094-0 · Cited by 20
Pauluhn, J. (2006) · Journal of Applied Toxicology · doi:10.1002/jat.1140 · Cited by 23
“This arrangement provides sufficient upstream sheath air and a first-stage dilution-cooling profile to prevent uncontrolled condensation of smoke onto the surfaces of the generation chamber and is conducive to maximize the condensation of semi- or low-volatile 1 mm H2O relative to ambient pressure.”
BackgroundMethodInfluentialPauluhn, J., & Möhr, U. (1999) · Experimental and Toxicologic Pathology · doi:10.1016/s0940-2993(99)80092-x · Cited by 19
Pauluhn, J., & Möhr, U. (2001) · Inhalation Toxicology · doi:10.1080/08958370151131891 · Cited by 19
Pauluhn, J. (1994) · Toxicology in Vitro · doi:10.1016/0887-2333(94)90231-3 · Cited by 18
Pauluhn, J., & Lewalter, J. (2002) · Experimental and Toxicologic Pathology · doi:10.1078/0940-2993-00242 · Cited by 17
Mohr, J. P. U. (1998) · Inhalation Toxicology · doi:10.1080/089583798197790 · Cited by 16
Pauluhn, J. (2004) · Archives of Toxicology · doi:10.1007/s00204-003-0516-1 · Cited by 14
“The respirability of liquid dispersion aerosol (pMDI, HMDI, TRIDI) was maximized by using a pre-separator/baffle system (Pauluhn 1994).”
MethodPauluhn, J. (2004) · Toxicology · doi:10.1016/j.tox.2004.08.012 · Cited by 13
Inhalation Toxicity of Propineb. Part I: Results of Subacute Inhalation Exposure Studies in Rats
Pauluhn, J., & Rosenbruch, M. (2003) · Inhalation Toxicology · doi:10.1080/08958370304465 · Cited by 13
“The MMAD and the GSD were calculated as described previously (Pauluhn, 1994).”
MethodPauluhn, U. M. J. (2001) · Inhalation Toxicology · doi:10.1080/089583701753210371 · Cited by 13
“The mass median aerodynamic diameter (MMAD) and the geometric standard deviation (GSD) were calculated as described previously (Pauluhn, 1994).”
MethodHazard Identification and Risk Assessment of Pyrethroids in the Indoor Environment
Pauluhn, J. (1998) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1998.10389573 · Cited by 13
Experimental and computational investigation of a nose-only exposure chamber
Lucci, F., Tan, W. T., Krishnan, S., Hoeng, J., Vanscheeuwijck, P., Jaeger, R. J., & Kuczaj, A. K. (2019) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1687843 · Cited by 13
“Pauluhn (1994) validated a 100-port (five-tier) system designed to host rats.”
BackgroundShort-term crocidolite inhalation studies in mice: validation of an inhalation chamber
Rihn, B. H., Kauffer, E., Martin, P., Coulais, C., Villa, M., Bottin, M. C., Vigneron, J. C., Edorh, A., & Martinet, N. (1996) · Toxicology · doi:10.1016/0300-483x(96)03325-2 · Cited by 12
Pauluhn, J. (2014) · Experimental and Toxicologic Pathology · doi:10.1016/j.etp.2014.03.001 · Cited by 11
“Details of this nose-only exposure system, ncluding its validation, have been published (Pauluhn, 1994; auluhn and Thiel, 2007).”
MethodPauluhn, J. (2017) · Toxicology Letters · doi:10.1016/j.toxlet.2017.10.003 · Cited by 12
Ueng, T., Wang, H.-W., Hung, C., & Chang, H.-L. (2004) · Journal of Toxicology and Environmental Health · doi:10.1080/15287390490441283 · Cited by 11
“The anodized aluminum inhalation chamber consisted of two concentric cylinders, essentially as described by Pauluhn (1994).”
Nose-Only Aerosol Exposure Systems: Design, Operation, and Performance
Phalen, R., Mendez, L. D. A., & Oldham, M. J. (2014) · CRC Press eBooks · doi:10.1201/b16781-3 · Cited by 9
“New designs have emerged, often for specific applications (e.g., Yeh et al., 1987; Pauluhn, 1994; Jaeger et al., 2005; Oldham et al., 2009; Werley et al., 2009; Stone et al., 2012).”
BackgroundKaur, R., Kaushik, A., Singh, K. K., Katare, O. P., & Singh, B. (2020) · AAPS PharmSciTech · doi:10.1208/s12249-019-1608-4 · Cited by 8
Pauluhn, J. (2002) · Toxicology · doi:10.1016/s0300-483x(02)00585-1 · Cited by 8
Pauluhn, J., & Vohr, H.-W. (2006) · Toxicology · doi:10.1016/j.tox.2006.08.031 · Cited by 6
Pauluhn, J. (2008) · Toxicology · doi:10.1016/j.tox.2008.01.023 · Cited by 5
Evaluation of twin-head electrospray nanoparticle disperser for nanotoxicity study
Liu, Q., Budiman, T., & Chen, D. (2014) · Journal of Nanoparticle Research · doi:10.1007/s11051-014-2556-2 · Cited by 2
“The even distribution and directed-flow design of the studied animal exposure chamber have been investigated by Pauluhn (Pauluhn 1994; Pauluhn and Thiel 2007).”
BackgroundWang, A., Gupta, A. B., Grimm, M. D., Pressburger, D. T., Sparrow, B., Richey, J. S., Shaw, J. R., Elsass, K. E., Roberts, G., Yao, P., et al. (2023) · Inhalation Toxicology · doi:10.1080/08958378.2023.2220735 · Cited by 3
“…with controllable exposure concentrations), various directed-flow, nose-only exposure models have been established for more efficient and targeted exposure in inhalation toxicity studies (Pauluhn 1994; Stone et al. 2012; Mainelis et al. 2013; Gavett et al. 2016; Lucci et al. 2020; Hu et al. 2021).”
BackgroundSubacute Inhalation Toxicity of 2-Chloro-4-Toluidine in Rats
Pauluhn, J. (2006) · Inhalation Toxicology · doi:10.1080/08958370600945838 · Cited by 1
“Details of the nose-only exposure system used have been published elsewhere (Pauluhn, 1994, 2004).”
MethodVogel, H. G. (2007) · Springer eBooks · doi:10.1007/978-3-540-70995-4_5 · Cited by 1
Pauluhn, J. (2002) · Encyclopedia of Agrochemicals · doi:10.1002/047126363x.agr142 · Cited by 1
Inhalation Toxicology of Alcohol/Gasoline Fuels- Current Status
Poon, R. W. M. (2005) · CRC Press eBooks · doi:10.1201/9781420037302.ch26
(2008) · CRC Press eBooks · doi:10.1201/9781420003260-12
Hamdaoui, Q. (2021) · theses.fr (ABES) · doi:10.70675/80460aadz3953z465dz98edz35fe1486c591 · Cited by 2
Bruse, K. D. (2015) · Springer eBooks · doi:10.1007/978-3-319-05392-9_23
Metadata
- Authors
- Pauluhn, J.
- Affiliations
- Bayer (Germany) (DE)
- Corresponding author
- Pauluhn, J.
- Venue
- Journal of Applied Toxicology
- Publisher
- Wiley
- Published
- 1994-01
- Volume
- 14
- Issue
- 1
- Pages
- 55-62
- ISSN
- 0260-437X (ISSN-L)
- 1099-1263
- OpenAlex
- W2022508295
- Cited by
- 65
- References
- 18
- Citations by year
- 2023: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 3 · 2012: 2
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Toxicology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Life Sciences › Immunology and Microbiology › Immunology › Immunotoxicology and immune responses
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Keywords
- aerosol collection, aerosol size distribution, air flow rate, inhalation toxicity testing, rats
- MeSH terms
- Administration, Inhalation, Aerosols, Air, Animals, Atmosphere Exposure Chambers, Computers, Humidity, Insecticides, Nitriles, Nose, Particle Size, Pyrethrins, Temperature, Rats, Wistar, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.