The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Novel current‐conducting composite substrates for exposing osteoblasts to alternating current stimulation
Abstract
The present study demonstrates that novel nanocomposites consisting of blends of polylactic acid and carbon nanotubes effectively can be used to expose cells to electrical stimulation. When osteoblasts cultured on the surfaces of these nanocomposites were exposed to electric stimulation (10 μA at 10 Hz) for 6 h/day for various periods of time, there was a 46% increase in cell proliferation after 2 days, a 307% increase in the concentration of extracellular calcium after 21 consecutive days, and upregulation of mRNA expression for collagen type‐I after both 1 and 21 consecutive days. These results provide evidence that electrical stimulation delivered through novel, current‐conducting polymer/nanophase composites promotes osteoblast functions that are responsible for the chemical composition of the organic and inorganic phases of bone. Furthermore, this evidence elucidates aspects of the cellular/molecular‐level mechanisms involved in new bone formation under electrical stimulation. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res 59: 499–506, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yasuda, H., Shima, N., Nakagawa, N., Mochizuki, S.-I., Yano, K., Fujise, N., Sato, Y., Goto, M., Yamaguchi, K., Kuriyama, M., et al. (1998) · Endocrinology · doi:10.1210/endo.139.3.5837 · Cited by 1,201
Cited by
The biocompatibility of carbon nanotubes
Smart, S. K., Cassady, A. I., Lu, G. Q., & Martin, D. J. (2006) · Carbon · doi:10.1016/j.carbon.2005.10.011 · Cited by 1,011
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Correa-Duarte, M. A., Wagner, N., Rojas-Chapana, J., Morsczeck, C., Thie, M., & Giersig, M. (2004) · Nano Letters · doi:10.1021/nl048574f · Cited by 481
Osteoblast function on electrically conductive electrospun PLA/MWCNTs nanofibers
Shao, S., Zhou, S., Li, L., Li, J., Luo, C., Wang, J., Li, X., & Weng, J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.051 · Cited by 320
Metadata
- Authors
- Supronowicz, P. R., Ajayan, P. M., Ullmann, K. R., Arulanandam, B. P., Metzger, D. W., & Bizios, R.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-12-06
- Volume
- 59
- Issue
- 3
- Pages
- 499-506
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2052974206
- Cited by
- 366
- References
- 1
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel current‐conducting composite substrates for exposing osteoblasts to alternating current stimulation. https://app.cochat.ai/papers/10.1002/jbm.10015
- The paper
- Supronowicz, P. R., Ajayan, P. M., Ullmann, K. R., Arulanandam, B. P., Metzger, D. W., & Bizios, R. (2002). Novel current‐conducting composite substrates for exposing osteoblasts to alternating current stimulation. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.