Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record.

Quantifying adhesive penetration in adhesive/dentin interface using confocal Raman microspectroscopy

Wang, Yong, Spencer, Paulette·2002·Journal of Biomedical Materials Research

Abstract

Confocal Raman microspectroscopy (CRM) provides an important and novel means of analyzing the chemical composition of the adhesive/dentin (a/d) interface. The purpose of this study was to develop a method for quantitative determination of the degree of adhesive penetration at the a/d interface using CRM. Three commercial dentin adhesive systems [Scotchbond Multipurpose Plus (SBMP+), Single Bond (SB), and Primer Bond NT (PBNT)] based on the total etch and “wet” bonding technique were examined in this study. Human dentin specimens treated with these adhesives were analyzed with CRM mapping across the a/d interface. Also, Raman spectra were collected on model mixtures of adhesive and type I collagen, and the ratios of the relative intensities of the Raman bands corresponding to adhesive and collagen were used for the construction of calibration curves. By comparing the Raman band ratios of interface specimens to the calibration curves, the percent of adhesive as a function of spatial position across the a/d interface was determined. The results show that there is a gradual decrease in penetration as a function of position for all three adhesive systems while the adhesive concentration gradient decreases in the order of SBMP+ > SB > PBNT. These differences in penetration of the three adhesives at the a/d interface also are discussed relative to the composition and phase segregation in adhesives. Additionally, our results indicate that confocal Raman microspectroscopy is a reliable in situ analytical technique for simple and rapid quantitative determination of adhesive penetration at its interface with prepared dentin. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res 59: 46–55, 2002

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.1215

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 213

Metadata

Authors
Wang, Y., & Spencer, P.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
2001-09-26
Volume
59
Issue
1
Pages
46-55
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2029849544
Cited by
213
References
0
FWCI
13.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantifying adhesive penetration in adhesive/dentin interface using confocal Raman microspectroscopy. https://app.cochat.ai/papers/10.1002/jbm.1215
The paper
Wang, Y., & Spencer, P. (2002). Quantifying adhesive penetration in adhesive/dentin interface using confocal Raman microspectroscopy. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.1215

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.