The DOI matches its Crossref record.
Effect of poly(ethylene glycol) molecular weight on tensile and swelling properties of oligo(poly(ethylene glycol) fumarate) hydrogels for cartilage tissue engineering
Abstract
This study was designed to determine the effect of changes in poly(ethylene glycol) (PEG) molecular weight on swelling and mechanical properties of hydrogels made from a novel polymer, oligo(poly(ethylene glycol) fumarate) (OPF), recently developed in our laboratory. Properties of hydrogels made from OPF with initial PEG molecular weights of 860, 3900, and 9300 were examined. The PEG 3900 formulation had a tensile modulus of 23.1 ± 12.4 kPa and percent elongation at fracture of 53.2 ± 13.7%; the PEG 9300 formulation had similar tensile properties (modulus: 16.5 ± 4.6 kPa, elongation: 76.0 ± 26.4%). However, the PEG 860 gels had a significantly higher modulus (89.5 ± 50.7 kPa) and a significantly smaller percent elongation at fracture (30.1 ± 6.4%), when compared with other formulations. Additionally, there were significant differences in percent swelling between each of the formulations. Molecular weight between crosslinks (Mc) and mesh size were calculated for each OPF formulation. Mc increased from 2010 ± 116 g/mol with PEG 860 to 6250 ± 280 g/mol with PEG 9300. Mesh size calculations showed a similar trend (76 ± 2 Å for PEG 860 to 160 ± 6 Å for PEG 9300). It was also found that these hydrogels could be laminated if a second layer was added before the first had completely crosslinked. Mechanical testing of these laminated gels revealed that the presence of an interfacial area did not significantly alter their tensile properties. These results suggest that the material properties of OPF‐based hydrogels can be altered by changing the molecular weight of PEG used in synthesis and that multilayered OPF hydrogel constructs can be produced, with each layer having distinct mechanical properties. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res 59: 429–437, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314
Cell Encapsulation in Biodegradable Hydrogels for Tissue Engineering Applications
Nicodemus, G. D., & Bryant, S. J. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0332 · Cited by 1,239
Review: Photopolymerizable and Degradable Biomaterials for Tissue Engineering Applications
Ifkovits, J. L., & Burdick, J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2007.0093 · Cited by 619
Novel Citric Acid‐Based Biodegradable Elastomers for Tissue Engineering
Yang, J., Webb, A. R., & Ameer, G. A. (2004) · Advanced Materials · doi:10.1002/adma.200306264 · Cited by 590
Biosynthetic hydrogel scaffolds made from fibrinogen and polyethylene glycol for 3D cell cultures
Almany, L., & Seliktar, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.047 · Cited by 551
Metadata
- Authors
- Temenoff, J. S., Athanasiou, K. A., Lebaron, R. G., & Mikos, A. G.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-11-15
- Volume
- 59
- Issue
- 3
- Pages
- 429-437
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2066223803
- Cited by
- 265
- References
- 0
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of poly(ethylene glycol) molecular weight on tensile and swelling properties of oligo(poly(ethylene glycol) fumarate) hydrogels for cartilage tissue engineering. https://app.cochat.ai/papers/10.1002/jbm.1259
- The paper
- Temenoff, J. S., Athanasiou, K. A., Lebaron, R. G., & Mikos, A. G. (2002). Effect of poly(ethylene glycol) molecular weight on tensile and swelling properties of oligo(poly(ethylene glycol) fumarate) hydrogels for cartilage tissue engineering. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.1259
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.