The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Identification of rapid changes at plasma–solid interfaces
Abstract
Recording ellipsometers and surface film balance, breath patterns, and ferric oxide powder “staining” were used to observe adsorption of normal plasma constituents onto metal oxide, silicon oxide, and polymer surfaces. Adsorbed proteins could be identified by their ability to adsorb matter from corresponding antihuman sera. Data indicate that oxidized silicon crystal surfaces adsorbed fibrinogen out of plasmas within 2 sec; within 20 sec, these films lost their ability to attract antifibrinogen and were later partially removed if intact factor XII was present in the solution. One aminated nonheparinized polymer formed films that adsorbed large amounts of fibrinogen and some gamma globulins out of plasma in the ellipsometer, and platelets out of platelet‐rich plasma, as well as ferric oxide out of aqueous suspension. After taking up heparin, these polymer films appeared able to adsorb only small amounts of protein or oxide, and no detectable amounts of fibrinogen or platelets. On another aminated polymer, heparin seemed without effect. Interaction of metal surfaces with plasma may be complicated by oxidation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McCrackin, F. L., Passaglia, E., Stromberg, R. R., et al. (1963) · Journal of Research of the National Bureau of Standards Section A Physics and Chemistry · doi:10.6028/jres.067a.040 · Cited by 618
PHYSICAL TECHNIQUES IN BIOLOGICAL RESEARCH
(1955) · Elsevier eBooks · doi:10.1016/b978-1-4832-3047-4.50001-9 · Cited by 326
Cited by
Surface engineering approaches to micropattern surfaces for cell-based assays
Falconnet, D., Csucs, G., Michelle Grandin, H., & Textor, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.024 · Cited by 944
Interaction of high molecular weight kininogen, factor XII, and fibrinogen in plasma at interfaces
Vroman, L., Adams, A., Fischer, G., & Munoz, P. (1980) · Blood · doi:10.1182/blood.v55.1.156.156 · Cited by 781
Self-citationThe Impact of Nanoparticle Protein Corona on Cytotoxicity, Immunotoxicity and Target Drug Delivery
Corbo, C., Molinaro, R., Parodi, A., Toledano Furman, N. E., Salvatore, F., & Tasciotti, E. (2016) · Nanomedicine · doi:10.2217/nnm.15.188 · Cited by 692
Modern biomaterials: a review—bulk properties and implications of surface modifications
Roach, P., Eglin, D., Rohde, K., & Perry, C. C. (2007) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-006-0064-3 · Cited by 562
Biomaterials in the development and future of vascular grafts
Xue, L., & Greisler, H. P. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.88 · Cited by 519
Metadata
- Authors
- Vroman, L., & Adams, A. L.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1969-03
- Volume
- 3
- Issue
- 1
- Pages
- 43-67
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2160455767
- Cited by
- 419
- References
- 2
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.