The DOI matches its Crossref record.
Tissue reaction to three ceramics of porous and non‐porous structures
Abstract
In this investigation, ceramics were studied to determine their role as rigid, abrasive implants in soft, living tissue. Discs and tubes of three ceramics, CaO·Al 2 O 3, CaO·TiO 2, and CaO·ZrO 2, were introduced as porous and non‐porous structures into muscle and connective tissue sites in rabbits. The animals were observed grossly to determine the duration of redness and swelling following surgery, and samples were retrieved at 1 week, 3 months, 6 months, and 9 months after implantation. A mild, acute inflammatory response immediately followed the implantation of all three materials in both the porous and non‐porous forms. Histological sections of the ceramics and surrounding tissue, cut and stained for light microscopy, demonstrated the absence of inflammatory cells and revealed the normal morphology and organization of the cells present around all types of implants tested. Tissue around discs of porous ceramics healed faster and exhibited thinner fibrous encapsulations than with impervious discs of the same material. Healthy fibrous connective tissue with an ample blood supply occupied those implants with pores of 45–100 mμ, and even more rapidly filled the samples with a 100‐ to 150‐μ pore size. The tissue ingrowth and tight adherence to the porous samples was believed responsible for the more moderate response to porous implants. No adverse responses of any kind were observed, except in a very few, atypical specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Jones, A. C., Arns, C. H., Hutmacher, D. W., Milthorpe, B. K., Sheppard, A. P., & Knackstedt, M. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.056 · Cited by 346
Almeida, C. R., Serra, T., Oliveira, M. I., Planell, J. A., Barbosa, M. A., & Navarro, M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.035 · Cited by 290
Kao, S. T., & Scott, D. D. (2007) · Oral and Maxillofacial Surgery Clinics of North America · doi:10.1016/j.coms.2007.06.002 · Cited by 263
Cao, H., Mchugh, K., Chew, S. Y., & Anderson, J. M. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32609 · Cited by 243
Metadata
- Authors
- Hulbert, S. F., Morrison, S. J., & Klawitter, J. J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1972-09
- Volume
- 6
- Issue
- 5
- Pages
- 347-374
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2036939733
- Cited by
- 421
- References
- 0
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue reaction to three ceramics of porous and non‐porous structures. https://app.cochat.ai/papers/10.1002/jbm.820060505
- The paper
- Hulbert, S. F., Morrison, S. J., & Klawitter, J. J. (1972). Tissue reaction to three ceramics of porous and non‐porous structures. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820060505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.