Cited by 243Electrospun Nanofibers in Biomedical ApplicationsBone Tissue Engineering MaterialsSilk-based biomaterials and applications

The topographical effect of electrospun nanofibrous scaffolds on the in vivo and in vitro foreign body reaction

Open access
Cao, Haoqing, Mchugh, Kevin, Chew, Sing Yian, Anderson, James M.·2010·Journal of Biomedical Materials Research Part A

Abstract

Topographical cues play an important role in influencing cellular behavior and are considered as significant parameters to be controlled in tissue engineering applications. This work investigated the biocompatibility with regard to scaffold architecture and topographical effect of nanofibrous scaffolds on the in vivo and in vitro foreign body reaction. Random and aligned polycaprolactone (PCL) nanofibers were fabricated by electrospinning technique, with diameters of 313 ± 5 nm and 506 ± 24 nm, respectively. Primary monocytes isolated from five human donors were cultured on PCL nanofibers, PCL film, and RGD‐coated glass in vitro and cell density and morphology was evaluated at time points of day 0 (2 h), day 3, day 7, and day 10. The in vivo study was carried out by implanting PCL nanofibers and film scaffolds subcutaneously in rats to test the biocompatibility and host response at time points of week 1, week 2, and week 4. The in vitro studies revealed that the initial monocyte adhesion on the aligned fiber scaffold was significantly less (p < 0.001) when compared to the random fiber scaffold. The in vivo study showed that the thicknesses of fibrous capsule on fibrous scaffolds were 7.55 ± 0.54 μm for aligned fibers and 4.13 ± 0.31 μm for random fibers, which were significantly thinner than that of film implants 37.7 ± 0.25 μm (p < 0.001). Additionally, cell infiltration was observed in aligned fibrous scaffolds both in vitro and in vivo, while on random fibers and films, distinct fibrous capsule boundaries were found on the surfaces. These results indicate that aligned electrospun nanofibers may serve as a promising scaffold for tissue engineering by minimizing host response, enhancing tissue‐scaffold integration, and eliciting a thinner fibrous capsule. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.32609

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. [6]Nishi O, Nishi K, Sakka Y, Sakuraba T, Maeda S. Intercapsular cataract surgery with lens epithelial cell removal part IV: Capsular fibrosis induced by poly(methyl methacrylate). J Cataract Refr Surg 1991; 17: 471– 477. 1895224
  2. [10]Anderson JM. Biological responses to materials. Ann Rev Mater Res 2001; 31: 81– 110.
  3. [14]DeFife KM, Colton E, Nakayama Y, Matsuda T, Anderson JM. Spatial regulation and surface chemistry control of mono-cyte/macrophage adhesion and foreign body giant. J Biomed Mater Res 1999; 45: 148– 154. 10397969
  4. [31]Su WT, Yang JY, Lin CD, Chu IM. Control cell behavior on physical topographical surface. JPN J Appl Phys 1 2004; 43: 3806– 3809.

Cited by

Sorted by citations

Authors
Cao, H., Mchugh, K., Chew, S. Y., & Anderson, J. M.
Affiliations
  • Nanyang Technological University (SG)
  • Case Western Reserve University (US)
Corresponding author
Chew, Sing Yian
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2009-09-18
Volume
93A
Issue
3
Pages
1151-1159
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2098655765
Cited by
243
References
33
Citations by year
2026: 1 · 2025: 9 · 2024: 13 · 2023: 10 · 2022: 14 · 2021: 15 · 2020: 18 · 2019: 18 · 2018: 12 · 2017: 21 · 2016: 23 · 2015: 24 · 2014: 19 · 2013: 13 · 2012: 11
FWCI
4.83
Type
journal article
Language
en
Open access
Locations
  • Journal of Biomedical Materials Research Part A (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Biomedical Imaging and Bioengineering (R01EB006365, EB006365-06A2)
Topics
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
Keywords
electrospun nanofibers, polycaprolactone, foreign body reaction, scaffold topography, aligned nanofibers, monocyte adhesion, fibrous capsule, biocompatibility, cell infiltration
MeSH terms
Animals, Cell Adhesion, Cell Count, Female, Foreign-Body Reaction, Humans, Inflammation, Macrophages, Materials Testing, Monocytes, Polyesters, Surface Properties, Wound Healing, Rats, Sprague-Dawley, Tissue Engineering, Cell Shape, Rats, Tissue Scaffolds, Nanofibers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review