Subacute toxicity testing of biomaterials using histopathologic evaluation of rabbit muscle tissue
The DOI matches its Crossref record.
Abstract
A group of 12 materials was evaluated for tissue compatibility via a sequential histopathologic evaluation of the rabit muscle response to the implanted materials. Tissue samples were obtained daily for 7 days and weekly for 12 weeks to follow the time course of the response. Some cytotoxic samples revealed a rapid and marked response of relatively short duration, whereas others tended to produce a sustained or a long‐term, intermittent inflammatory and/or necrotic response. These effects also demonstrated the suitability of 7 days as a satisfactory time period for routine evaluation of rabbit muscle reaction to implanted materials. The histopathologic evaluation of the response was compared with a gross evaluation of the implant site and an independent test of the material by tissue culture (agar–overlay method).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Tissue response to implanted polymers: The significance of sample shape
Matlaga, B. F., Yasenchak, L. P., & Salthouse, T. N. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100308 · Cited by 295
The foreign body reaction: A chronic inflammatory response
Coleman, D. L., King, R. N., & Andrade, J. D. (1974) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820080503 · Cited by 286
In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181
Metadata
- Authors
- Turner, J. E., Lawrence, W. H., & Autian, J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1973-01
- Volume
- 7
- Issue
- 1
- Pages
- 39-58
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2098821429
- Cited by
- 85
- References
- 0
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.