Postyield behavior of subchondral trabecular bone
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cylindrical specimens of bovine subchondral trabecular bone were tested to uniaxial compressive strain levels of 75% to study energy absorption during pore collapse. Stress–strain curves were characterized by macroscopic yield at about 8% strain followed by a significant horizontal pore collapse regime. Energy absorption occurred largely in this postyield regime. Yield strength and energy absorption capacity were found to increase linearly with specimen apparent density. Microstructural analysis of the deformed specimens verified that the mechanism for energy absorption was primarily fracture and buckling of trabeculae. The results suggest that during fracture, the collapse of trabecular bone (and the consequent absorption of energy) serves to attenuate stresses transmitted through the skeleton and thus protect vital structures such as the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variations in strength and structure of cancellous bone at the knee
Behrens, J. C., Walker, P. S., & Shoji, H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90010-4 · Cited by 171
Cited by
Biomimetic porous scaffolds for bone tissue engineering
Wu, S., Liu, X., Yeung, K. W. K., Liu, C., & Yang, X. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.04.001 · Cited by 1,159
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Woodard, J. R., Hilldore, A. J., Lan, S. K., Park, C. J., Morgan, A. W., Eurell, J. A. C., Clark, S. G., Wheeler, M. B., Jamison, R. D., & Wagoner Johnson, A. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.021 · Cited by 829
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Frost, H. M. (1990) · The Anatomical Record · doi:10.1002/ar.1092260403 · Cited by 478
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
“This is in line with earlier findings [28,97,20,119,3,24,39,118].”
ResultThe mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215
Schwiedrzik, J., Raghavan, R., Bürki, A., LeNader, V., Wolfram, U., Michler, J., & Zysset, P. (2014) · Nature Materials · doi:10.1038/nmat3959 · Cited by 182
(1997) · Cellular Solids · doi:10.1017/cbo9781139878326.013 · Cited by 16
Post-yield relaxation behavior of bovine cancellous bone
Burgers, T. A., Lakes, R. S., García-Rodríguez, S., Piller, G. R., & Ploeg, H.-L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.005 · Cited by 10
“Monotonic mechanical loading into the post-yield region of cancellous bone has been reported by a number of authors (Hayes and Carter, 1976; Fyhrie and Schaffler, 1994; Keaveny et al., 1994, 1999; Keyak et al., 1996; Burgers et al., 2008).”
Background
Metadata
- Authors
- Hayes, W. C., & Carter, D. R.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1976-07
- Volume
- 10
- Issue
- 4
- Pages
- 537-544
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1963749253
- Cited by
- 101
- References
- 1
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.