The DOI matches its Crossref record.
The interaction of plasma proteins with polymers. I. Relationship between polymer surface energy and protein adsorption/desorption
Abstract
Adsorption of bovine albumin, γ‐globulin and fibrinogen from phosphate buffer solution (pH = 7.5) onto several polymer films was studied using the radioiodinated proteins (125 I). The kinetics of desorption of the proteinated polymer films in bovine plasma was determined. Contact angle measurements on these same polymers allowed the calculation of dispersive (W) and polar (Ip) components of the polymer‐protein solution system. Results from these measurements show that the nondispersive‐dispersive force balance at the polymer‐protein solution interface, expressed by the Ip/W ratio, is an important factor for binding of proteins on polymer surfaces. The purity of fibrinogen and the cleaning procedures for the polymer surfaces influence the absolute values of proteins adsorbed on polymer surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Adsorption of proteins from solution at the solid-liquid interface
Norde, W. (1986) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(86)80012-4 · Cited by 1,102
Globular proteins at solid/liquid interfaces
Haynes, C. A., & Norde, W. (1994) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/0927-7765(94)80066-9 · Cited by 852
Tanaka, M., Motomura, T., Kawada, M., Anzai, T., Kasori, Y., Shiroya, T., Shimura, K., Onishi, M., & Mochizuki, A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00031-4 · Cited by 516
Hemocompatibility of titanium oxide films
Huang, N., Yang, P., Leng, Y. X., Chen, J. Y., Sun, H., Wang, J., Wang, G. J., Ding, P. D., Xi, T. F., & Leng, Y. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00046-2 · Cited by 404
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Why proteins prefer interfaces
Norde, W., & Lyklema, J. (1991) · Journal of Biomaterials Science, Polymer Edition · doi:10.1080/09205063.1991.9756659 · Cited by 371
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302
Metadata
- Authors
- Baszkin, A., & Lyman, D. J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1980-07
- Volume
- 14
- Issue
- 4
- Pages
- 393-403
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2025684292
- Cited by
- 197
- References
- 0
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.