The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Toxicology and biocompatibility of bioglasses
Abstract
Evidence for the lack of toxicity of various bioglass formulations has been deduced from studies carried out, both in vivo and in vitro, in several different centers. Recent studies of the authors, described here, include testing of solid bioglass implants in the soft tissues of rats and rabbits for time periods of up to eight weeks. Two new techniques are described for the toxicological testing of particulate biomaterials. These tests, which involve rat peritoneal macrophages in culture and a mouse pulmonary biomaterial embolus model, indicate the biocompatibility of bioglass powders. Thus, the surface activity so critical in bone adhesion is without toxic effect in nonosseous tissues in contact with solid bioglass implants. Should wear occur and produce particulate bioglass, the material should be eliminated without consequence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonding mechanisms at the interface of ceramic prosthetic materials
Hench, L. L., Splinter, R. J., Allen, W. C., & Greenlee, T. K. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050611 · Cited by 3,251
Self-citation(1993) · Elsevier eBooks · doi:10.1016/c2009-0-03338-8 · Cited by 2,158
Direct chemical bond of bioactive glass‐ceramic materials to bone and muscle
Hench, L. L., & Paschall, H. A. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070304 · Cited by 942
Self-citationBailey, W. S. (1964) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.1964.13.904 · Cited by 397
Effect of fibronectin on the adhesion of an established cell line to a surface reactive biomaterial
Seitz, T. L., Noonan, K. D., Hench, L. L., & Noonan, N. E. (1982) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820160303 · Cited by 84
Self-citationThe foreign body reaction—an experimental protocol
Coleman, D. L., King, R. N., & Andrade, J. D. (1974) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820080308 · Cited by 42
The New Field of Plastics Toxicology - Methods and Results
Autian, J., & Guess, W. L. (1973) · Critical Reviews in Toxicology · doi:10.1080/10408447309163830 · Cited by 37
Cited by
Bioceramics: From Concept to Clinic
Hench, L. L. (1991) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1991.tb07132.x · Cited by 4,977
Self-citationBiodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Hench, L. L. (1998) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1998.tb02540.x · Cited by 2,652
Self-citationHench, L. L. (2006) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-006-0432-z · Cited by 2,505
Self-citationSuchanek, W., & Yoshimura, M. (1998) · Journal of Materials Research · doi:10.1557/jmr.1998.0015 · Cited by 2,028
Metadata
- Authors
- Wilson, J., Pigott, G. H., Schoen, F. J., & Hench, L. L.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1981-11
- Volume
- 15
- Issue
- 6
- Pages
- 805-817
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2140193218
- Cited by
- 468
- References
- 7
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.