Scanning electron microscopic study of the hydrolytic degradation of poly(glycolic acid) suture
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This article reports the morphological observations on the surface changes of poly(glycolic acid) sutures which have been exposed to various dosages of γ irradiation (0, 2.5, 5.0, 10, 20, and 40 Mrad) and duration of immersion (0, 7, 14, 28, 48, 60, and 90 days) in a physiological saline buffer. The most important gross morphological characteristics of PGA suture hydrolytic degradation is the formation of surface cracks on the filaments. The regularity of the surface cracks increased with an increase in the γ irradiation and the duration of hydrolysis. Surface cracks were not observed in irradiated sutures that had not been subjected to hydrolytic degradation. The arrangement of the surface cracks, their orientation on the filaments, and the direction of crack propagation provide very useful information for depicting the mechanism of hydrolytic degradation in this class of fibrous material. The microfibrillar model of fiber structure has been used as the basis for the proposed degradation mechanism of PGA in vitro. It is believed that hydrolysis occurs initially in the amorphous regions sandwiched between two crystalline zones, as tie‐chain segments, free chain ends, and chain folds in these regions degrade into fragments. As degradation proceeds, the size of the fragments reaches the stage at which they can be dissolved into the buffer medium. This dissolution removes the fragments from the amorphous regions, and surface cracks appeared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Cited by
Arifin, D. Y., Lee, L. Y., & Wang, C.-H. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.007 · Cited by 674
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Holland, S. J., Tighe, B. J., & Gould, P. L. (1986) · Journal of Controlled Release · doi:10.1016/0168-3659(86)90001-5 · Cited by 478
Pitt, C. G., & Zhong-wei, G. (1987) · Journal of Controlled Release · doi:10.1016/0168-3659(87)90020-4 · Cited by 248
Biodegradable Implants in Sports Medicine: The Biological Base
Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., Helling, H.-J., & Südkamp, N. P. (2000) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(00)90055-0 · Cited by 236
Metadata
- Authors
- Chu, C. C., & Campbell, N. D.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1982-07
- Volume
- 16
- Issue
- 4
- Pages
- 417-430
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2095029373
- Cited by
- 121
- References
- 1
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.