Physicochemical characterization and in vivo blood tolerability of cast and extruded biomer
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Solution grade and extruded grade Biomer (SB and EB, respectively) are polyurethanes that have been suggested for use in biomedical applications. The bulk materials were examined by elemental analysis, differential scanning calorimetry, thermomechanical testing, and stress‐strain testing. The extruded grade material has a lower soft segment molecular weight (650 g/mol) than the solution grade material (2000 g/mol). As a result of its higher molecular weight, the soft segment phase of SB is semicrystalline in the solid state. The hard segments of the extruded grade material are chain extended with water yielding a lower urea concentration than in the solution grade material in which the hard segments are chain extended with diamines. Chemical structures for the two materials consistent with elemental analysis, urea/urethane ratios and thermal and mechanical data, are proposed. X‐ray photoelectron spectroscopy (ESCA) was used to analyze the surfaces of extruded grade Biomer, solution grade Biomer cast on the inner surface of polyethylene tubing, and extruded grade Biomer dissolved in DMA and similarly cast on polyethylene (CB). Soft segment concentrations were highest on the EB surface and lowest on the SB surface. Soft segment concentrations on the EB surface were higher than on the CB surface, indicating that the method of fabrication affected the composition of the surface layer. The three materials were tested for blood tolerance in a canine femoral arteriovenous shunt configuration. Blood compatibility was correlated with increasing concentration of polyether soft segments on the surface.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Variations in PEU blood compatibility have been observed, with improved thromboresistance correlating to more alkylated soft segments [82], higher soft segment content on the surface [83] and surface treatment, such as grafted sulfonate groups [84,85].”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [85]
Citations
Cites
Identification and Analysis of Plastics
Haslam, J., & Willis, H. A. (1965) · International Linear Collider · Cited by 220
Dynamic mechanical properties of polyurethane block polymers
Huh, D. S., & Cooper, S. L. (1971) · Polymer Engineering & Science · doi:10.1002/pen.760110504 · Cited by 202
Self-citationA technique for the characterization of hydrophilic solid surfaces
Hamilton, W. C. (1972) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(72)90011-2 · Cited by 200
In vivo evaluation of artificial surfaces with a nonhuman primate model of arterial thrombosis.
Hanson, S. R., Harker, L. A., Ratner, B. D., & Hoffman, A. S. (1980) · PubMed · Cited by 192
Contact angles at the solid—water interface
Andrade, J. D., Ma, S. M., King, R. N., & Gregonis, D. E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90350-3 · Cited by 188
Annealing-induced morphological changes in segmented elastomers
Van Bogart, J. W. C., Bluemke, D. A., & Cooper, S. L. (1981) · Polymer · doi:10.1016/0032-3861(81)90250-0 · Cited by 168
Self-citationIdentification and analysis of plastics
Brame, E. G. (1966) · Journal of Colloid and Interface Science · doi:10.1016/0095-8522(66)90093-6 · Cited by 147
Lyman, D. J., Muir, W. M., & Lee, I. J. (1965) · ASAIO Journal · doi:10.1097/00002480-196504000-00056 · Cited by 109
Surface and bulk characteristics of a polyether urethane for artificial hearts
BORETOS, J. W., Pierce, W. S., Baier, R. E., LeRoy, A. F., & Donachy, H. J. (1975) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820090308 · Cited by 89
Segmented polyurethane: A polyether polymer, II. Two years experience
BORETOS, J. W., Detmer, D. E., & Donachy, J. H. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050408 · Cited by 87
Some species differences in fibrinolysis and blood coagulation
Mason, R. G., & Read, M. S. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050109 · Cited by 73
Past, present and future role of polyurethanes for surgical implants
BORETOS, J. W. (1980) · Pure and Applied Chemistry · doi:10.1351/pac198052071851 · Cited by 51
Surface spectroscopic studies of Biomer
Graham, S. W., & Hercules, D. M. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150403 · Cited by 46
Transient in vivo protein adsorption onto polymeric biomaterials
Ihlenfeld, J. V., & Cooper, S. L. (1979) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820130405 · Cited by 43
Self-citationPolyether—polyurethane surfaces: Thrombin adsorption, platelet adsorption, and ESCA scanning
Costa, V. S. D., Brier, D., Trudel, G., Waugh, D. F., Salzman, E. W., & Merrill, E. W. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90402-6 · Cited by 39
Measurement of transient thrombus deposition on polymeric materials
Ihlenfeld, J. V., Mathis, T. R., Riddle, L. M., & Cooper, S. L. (1979) · Thrombosis Research · doi:10.1016/0049-3848(79)90013-6 · Cited by 39
Self-citationHuman vs. dog platelet adhesion to Cuprophane under controlled conditions of whole blood flow.
Ef, G., Herther, K. K., & Didisheim, P. (1976) · PubMed · Cited by 37
Transient in vivo thrombus deposition onto polymeric biomaterials: role of plasma fibronectin.
Ihlenfeld, J. V., Mathis, T. R., Barber, T. A., Mosher, D. F., Riddle, L. M., Hart, A. P., Updike, S. J., & Cooper, S. L. (1978) · PubMed · Cited by 30
Self-citationThermally induced time dependence of mechanical properties in biomedical grade polyurethanes
Wilkes, G. L., Dziemianowicz, T. S., Ophir, Z., Artz, E., & Wildnauer, R. H. (1979) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820130204 · Cited by 25
A Critical Study of Segmented Polyurethanes
Merrill, E. W., Costa, V. S. D., Salzman, E. W., Brier, D., KUCHNER, L., Waugh, D. F., TRUDEL, G., STOPPER, S., & Vitale, V. (1982) · Advances in chemistry series · doi:10.1021/ba-1982-0199.ch008 · Cited by 24
Thin polymer films for transmission infrared spectroscopy
Koberstein, J. T., Cooper, S. L., & Shen, M. C. (1975) · Review of Scientific Instruments · doi:10.1063/1.1134128 · Cited by 20
Self-citationLaser Desorption Mass Spectra of Biomedical Polymers: Biomer and Avcothane
Graham, S. W., & Hercules, D. M. (1982) · Spectroscopy Letters · doi:10.1080/00387018208062643 · Cited by 11
Transient thrombus deposition on chitosan-heparin coated polyethylene.
Lk, L., Br, Y., Df, M., Hart, A. P., Hammar, W. J., & Sl, C. (1981) · PubMed · Cited by 8
Copolyether-Urethanes as Materials for Artificial Hearts
Kolff, T., Burkett, G., & Feyen, J. (1973) · Biomaterials Medical Devices and Artificial Organs · doi:10.3109/10731197309118569 · Cited by 7
Research works printed but not linked: 2
- Pierce W. S., 1967, Trans. ASAIO, 13, 299
- Hanson S. R., 1980, In‐vivo evaluation of artificial surfaces with a nonhuman primate model of arterial thrombosis, J. Lab. Clin. Med., 95, 289
Cited by
Polyurethanes in Biomedical Applications
Burke, A., & Hasirci, N. (2004) · Advances in Experimental Medicine and Biology · doi:10.1007/978-0-306-48584-8_7 · Cited by 494
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Shape Memory Materials for Biomedical Applications
El Feninat, F., Laroche, G., Fiset, M., & Mantovani, D. (2002) · Advanced Engineering Materials · doi:10.1002/1527-2648(200203)4:3<91::aid-adem91>3.0.co;2-b · Cited by 458
Selected topics in biomedical polyurethanes. A review
Gogolewski, S. (1989) · Colloid & Polymer Science · doi:10.1007/bf01410115 · Cited by 230
Bouchemal, K., Briançon, S., Perrier, E., Fessi, H., Bonnet, I., & Zydowicz, N. (2004) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2003.09.025 · Cited by 192
Metadata
- Authors
- Lelah, M. D., Lambrecht, L. K., Young, B. R., & Cooper, S. L.
- Affiliations
- University of Wisconsin–Madison (US)
- ORCID
- Young, Brian R.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 17
- Issue
- 1
- Pages
- 1-22
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2047719288
- Cited by
- 134
- References
- 24
- Citations by year
- 2023: 1 · 2022: 2 · 2018: 1 · 2017: 1 · 2015: 1 · 2013: 1
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
- Keywords
- Biomer, polyurethane, soft segment molecular weight, surface composition, hemocompatibility, arteriovenous shunt, chain extension
- MeSH terms
- Animals, Biocompatible Materials, Blood Platelets, Calorimetry, Differential Scanning, Chemistry, Physical, Dogs, Fibrinogen, Microscopy, Electron, Scanning, Polyurethanes, Spectrophotometry, Infrared, Stress, Mechanical, Surface Properties, Thrombosis, Chemical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.