CoChat

Physicochemical characterization and in vivo blood tolerability of cast and extruded biomer

Lelah, Michael D., Lambrecht, Linda K., Young, Brian R., Cooper, Stuart L. · 1983 · Journal of Biomedical Materials Research

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Solution grade and extruded grade Biomer (SB and EB, respectively) are polyurethanes that have been suggested for use in biomedical applications. The bulk materials were examined by elemental analysis, differential scanning calorimetry, thermomechanical testing, and stress‐strain testing. The extruded grade material has a lower soft segment molecular weight (650 g/mol) than the solution grade material (2000 g/mol). As a result of its higher molecular weight, the soft segment phase of SB is semicrystalline in the solid state. The hard segments of the extruded grade material are chain extended with water yielding a lower urea concentration than in the solution grade material in which the hard segments are chain extended with diamines. Chemical structures for the two materials consistent with elemental analysis, urea/urethane ratios and thermal and mechanical data, are proposed. X‐ray photoelectron spectroscopy (ESCA) was used to analyze the surfaces of extruded grade Biomer, solution grade Biomer cast on the inner surface of polyethylene tubing, and extruded grade Biomer dissolved in DMA and similarly cast on polyethylene (CB). Soft segment concentrations were highest on the EB surface and lowest on the SB surface. Soft segment concentrations on the EB surface were higher than on the CB surface, indicating that the method of fabrication affected the composition of the surface layer. The three materials were tested for blood tolerance in a canine femoral arteriovenous shunt configuration. Blood compatibility was correlated with increasing concentration of polyether soft segments on the surface.

Overview

Integrity signals

Registry

Crossref · 10.1002/jbm.820170102

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 2

  1. Pierce W. S., 1967, Trans. ASAIO, 13, 299
  2. Hanson S. R., 1980, In‐vivo evaluation of artificial surfaces with a nonhuman primate model of arterial thrombosis, J. Lab. Clin. Med., 95, 289

Cited by

Metadata

Authors
Lelah, M. D., Lambrecht, L. K., Young, B. R., & Cooper, S. L.
Affiliations
University of Wisconsin–Madison (US)
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1983-01
Volume
17
Issue
1
Pages
1-22
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2047719288
Cited by
134
References
24
Citations by year
2023: 1 · 2022: 2 · 2018: 1 · 2017: 1 · 2015: 1 · 2013: 1
FWCI
9.21
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
Keywords
Biomer, polyurethane, soft segment molecular weight, surface composition, hemocompatibility, arteriovenous shunt, chain extension
MeSH terms
Animals, Biocompatible Materials, Blood Platelets, Calorimetry, Differential Scanning, Chemistry, Physical, Dogs, Fibrinogen, Microscopy, Electron, Scanning, Polyurethanes, Spectrophotometry, Infrared, Stress, Mechanical, Surface Properties, Thrombosis, Chemical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.