Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 259

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Direct electron microscopy studies of the bone—hydroxylapatite interface

Tracy, B. M., Doremus, R. H. · 1984 · Journal of Biomedical Materials Research

Abstract

The bone‐hydroxylapatite interface has been examined directly in the transmission electron microscope (TEM). The bone—hydroxylapatite interface was characterized by using several electron microscopy techniques, including bright and dark field imaging, electron diffraction, high‐resolution imaging, and energy dispersive analysis in the scanning‐transmission electron microscope (STEM EDS). Mechanical grinding followed by argon‐ion milling produced interface regions of unstained and undecalcified rat bone and hydroxylapatite that were transparent to electrons. Thus the exact location of the interface could be established and the bone at the interface studied. Conventional and high‐resolution imaging in the TEM demonstrated direct chemical bonding between bone and hydroxylapatite. The bone at the ceramic surface was the same as normal bone away from the interface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820180702

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 259

Metadata

Authors
Tracy, B. M., & Doremus, R. H.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1984-09
Volume
18
Issue
7
Pages
719-726
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2071689334
Cited by
259
References
4
FWCI
6.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.