In vivo biocompatibility studies. VII. Inflammatory response to polyethylene and to a cytotoxic polyvinylchloride
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The cellular biocompatibility of low‐density polyethylene and a cytotoxic polyvinylchloride were investigated using an in vivo cage implant system. Components of the inflammatory response (white cells, extracellular alkaline and acid phosphatase, the complement component C3, and total protein content) were monitored over a 21‐day implantation period. Scanning electron microscopy was used to evaluate the morphologic condition of leukocytes adherent to the implanted polymers. Prior to implantation, each polymer was evaluated using an established primary acute toxicity screen. The results showed that the cytotoxic polyvinylchloride stimulated an intense acute phase inflammatory response, and at later observation periods, an intense and increasing chronic inflammatory response. In constrast, the polyethylene promoted relatively small increases in the acute and chronic phases of inflammation; the overall cellular response being essentially resolved by the third week after implantation. The initial toxicity screen of each polymer suggested that the observed differences in inflammation were primarily caused by the release from the polyvinylchloride of the added cytotoxic agent (dioctyltinbisoctylmercaptoacetate).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue response to implanted polymers: The significance of sample shape
Matlaga, B. F., Yasenchak, L. P., & Salthouse, T. N. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100308 · Cited by 295
In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181
Self-citation
Cited by
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
Design, clinical translation and immunological response of biomaterials in regenerative medicine
Sadtler, K., Singh, A., Wolf, M. T., Wang, X., Pardoll, D. M., & Elisseeff, J. H. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.40 · Cited by 319
Chitosan based metallic nanocomposite scaffolds as antimicrobial wound dressings
Mohandas, A., Deepthi, S., Biswas, R., & Jayakumar, R. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.11.003 · Cited by 267
Hydrogels in healthcare: From static to dynamic material microenvironments
Kirschner, C. M., & Anseth, K. S. (2013) · Acta Materialia · doi:10.1016/j.actamat.2012.10.037 · Cited by 255
Building a Bridge: Engineering Spinal Cord Repair
Geller, H. M., & Fawcett, J. W. (2002) · Experimental Neurology · doi:10.1006/exnr.2002.7865 · Cited by 206
Metadata
- Authors
- Marchant, R. E., Anderson, J. M., & Dillingham, E. O.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1986-01
- Volume
- 20
- Issue
- 1
- Pages
- 37-50
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2116660863
- Cited by
- 60
- References
- 2
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.