A new canine model to evaluate the biological response of intramedullary bone to implant materials and surfaces
The DOI matches its Crossref record.
Abstract
A new canine model utilizing an implantable chamber with multiple bone in‐growth channels has been used to study the response of intramedullary bone to various implant materials and surfaces. The first group of dogs received implants containing channels lined by smooth‐surfaced coupons of titanium, titanium alloy, sputter‐hydroxyapatite‐coated (HA‐coated) titanium alloy, and polyethylene. A pattern of early initial bone ingrowth by 2 weeks, becoming maximal at 6 to 12 weeks with remodeling to a more mature lamellar bone, and later resorption by 24 weeks was seen for all test groups, with fibrous tissue interfaces covering the smooth test coupons at all time points. Significantly increased bone ingrowth in the sputter‐HA coated group was found only at 6 weeks. The second group of dogs received implants with channels lined by surfaceroughened coupons of either titanium or plasma‐HA‐coated titanium, half of which were also packed with a crystalline‐HA grouting at the time of surgery. At both 6 and 12 weeks, bone ingrowth was greatly enhanced by the presence of the plasma‐HA coating or the crystalline‐HA grouting as compared to the uncoated titanium channels. Histologically, bone was seen to bond directly to the plasma‐HA coating and the crystalline‐HA grouting. A thin fibrous tissue layer was noted between bone and the titanium in most areas, but evidence of direct bone contact to the metal surface was seen. Mechanical testing in tension of intact coupon‐‐bone‐‐coupon units revealed significant strength of the bone‐‐plasma‐‐HA bond, with failure initiating at the metal‐HA interface with forces of 15.3 N at 6 weeks, increasing to 44.8 N at 12 weeks. Plasma‐HA‐lined channels with crystalline‐HA packing required similar forces for failure. No significant adhesion strength was noted for the titanium channels at 6 weeks, and only the crystalline‐HA‐filled channels displayed measurable strength of the bone‐‐titanium interface at 12 weeks, with a force of 9 N needed for failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
Physico-chemical considerations of titanium as a biomaterial
Tengvall, P., & Lundström, I. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90056-y · Cited by 373
Yildirimer, L., & Seifalian, A. M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.04.014 · Cited by 98
“already demonstrated long-term dramatic reductions of biocompatibility, likely due to degradation products causing bone resorption in and around the implant site (Spivak et al., 1990).”
BackgroundStimulation of monocytes and macrophages: possible influence of surface roughness
Fink, J., Fuhrmann, R., Scharnweber, T., & Franke, R. P. (2008) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2008-1090 · Cited by 38
Liu, J. Q., Luo, Z., Cui, F. Z., Duan, X., & Peng, L. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200010)52:1<115::aid-jbm14>3.0.co;2-x · Cited by 18
Metadata
- Authors
- Spivak, J. M., Ricci, J. L., Blumenthal, N. C., & Alexander, H.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-09
- Volume
- 24
- Issue
- 9
- Pages
- 1121-1149
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2082908350
- Cited by
- 109
- References
- 0
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new canine model to evaluate the biological response of intramedullary bone to implant materials and surfaces. https://app.cochat.ai/papers/10.1002/jbm.820240902
- The paper
- Spivak, J. M., Ricci, J. L., Blumenthal, N. C., & Alexander, H. (1990). A new canine model to evaluate the biological response of intramedullary bone to implant materials and surfaces. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820240902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.