Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Stimulation of monocytes and macrophages: Possible influence of surface roughness

Fink, J., Fuhrmann, R., Scharnweber, T., Franke, R.P. · 2008 · Clinical Hemorheology and Microcirculation

Abstract

The aim of this study was to understand the mechanisms of interaction of monocytes/macrophages and foreign body giant cell (FBGC) with implant materials, with respect to the roughness and the solubility of calcium phosphate based coatings. Anderson et al. (Bone Engineering, J.E. Davies, ed., Toronto, 2000, pp. 81–93) showed that the presence of FBGC's and monocytes/macrophages influenced the strength of the implant-tissue integration and that more monocytes/macrophages rested on smooth surfaces compared to rough surfaces. We seeded human bone marrow cells on uncoated ultrasmooth polished TiAl6V4 samples as well as on coated TiAl6V4 discs of the same diameter with two different calcium phosphates coatings, monetite (DCP) and hydroxyapatite (OHAp), both with rougher surfaces. On uncoated ultrasmooth polished TiAl6V4 discs (UUTi, diameter 16 mm, thickness 2 mm) and on TiAl6V4 discs of same diameter coated with OHAP or DCPA, human bone marrow cells (HMBC) were seeded and cultivated under standard culture conditions for 90 days without addition of inducing substances like ascorbic acid, Na-β-glycerophosphate or dexamethasone. The roughnesses of the virgin samples were assessed with atomic force microscopy and light profilometry. After 90 days of cultivation a fraction of the samples, with cells and extracellular matrix, were stained with hematoxylin eosin (HE) and examined in light microscopy. R a roughness values of virgin uncoated TiAl6V4 samples were 0.001 μm, of DCP coated discs 4 μm and of OHAp coated discs 3 μm. The examination of HE stained samples showed a high number of FBGC and monocytes/macrophages on the UUTi samples. On the DCP coated samples there were less FBGC and monocytes/macrophages and on the OHAp coated samples we could not find any FBGC and monocytes/macrophages. The extracellular matrix (ECM) we found on the UUTi samples was finer and thinner than on the coated samples. The ECM was vastly spread and not dense on the UUTi samples in contrast to the calcium phosphate coated samples, where the ECM was much thicker and stronger. The ultrasmooth surface of the uncoated TiAl6V4 samples, a material which is accepted to be biocompatible, evidently induced the differentiation of cells of the monocytic lineage and the formation of FBGC out of the cell populations present in the human bone marrow.

Overview

Integrity signals

Registry

Crossref · 10.3233/ch-2008-1090

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 4 references

Cited by

See all 43

Metadata

Authors
Fink, J., Fuhrmann, R., Scharnweber, T., & Franke, R. P.
Affiliations
  • Universität Ulm (DE)
  • Institute for Biological Interfaces, Forschungszentrum Karlsruhe GmbH, Karlsruhe, Germany
Venue
Clinical Hemorheology and Microcirculation
Published
2008-06
Volume
39
Issue
1-4
Pages
205-212
ISSN
  • 1386-0291 (ISSN-L)
  • 1875-8622
OpenAlex
W81993338
Cited by
38
References
4
Citations by year
2025: 3 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 1 · 2013: 1
FWCI
1.33
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Clinical Hemorheology and Microcirculation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
monocytes, macrophages, foreign body giant cells, surface roughness, calcium phosphate coatings, hydroxyapatite, monetite, titanium implants, TiAl6V4, bone marrow cells, extracellular matrix, cell differentiation, biocompatibility, cell adhesion, osteoinduction, osteogenic differentiation, osteoclastogenesis
MeSH terms
Alloys, Biocompatible Materials, Bone Marrow Cells, Calcium Phosphates, Extracellular Matrix, Humans, Macrophages, Materials Testing, Monocytes, Solubility, Surface Properties, Titanium, X-Ray Diffraction, Giant Cells, Foreign-Body, Durapatite, Cell Culture Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stimulation of monocytes and macrophages: Possible influence of surface roughness. https://app.cochat.ai/papers/10.3233/ch-2008-1090
The paper
Fink, J., Fuhrmann, R., Scharnweber, T., & Franke, R. P. (2008). Stimulation of monocytes and macrophages: Possible influence of surface roughness. Clinical Hemorheology and Microcirculation. https://doi.org/10.3233/ch-2008-1090

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.