The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Stimulation of monocytes and macrophages: Possible influence of surface roughness
Abstract
The aim of this study was to understand the mechanisms of interaction of monocytes/macrophages and foreign body giant cell (FBGC) with implant materials, with respect to the roughness and the solubility of calcium phosphate based coatings. Anderson et al. (Bone Engineering, J.E. Davies, ed., Toronto, 2000, pp. 81–93) showed that the presence of FBGC's and monocytes/macrophages influenced the strength of the implant-tissue integration and that more monocytes/macrophages rested on smooth surfaces compared to rough surfaces. We seeded human bone marrow cells on uncoated ultrasmooth polished TiAl6V4 samples as well as on coated TiAl6V4 discs of the same diameter with two different calcium phosphates coatings, monetite (DCP) and hydroxyapatite (OHAp), both with rougher surfaces. On uncoated ultrasmooth polished TiAl6V4 discs (UUTi, diameter 16 mm, thickness 2 mm) and on TiAl6V4 discs of same diameter coated with OHAP or DCPA, human bone marrow cells (HMBC) were seeded and cultivated under standard culture conditions for 90 days without addition of inducing substances like ascorbic acid, Na-β-glycerophosphate or dexamethasone. The roughnesses of the virgin samples were assessed with atomic force microscopy and light profilometry. After 90 days of cultivation a fraction of the samples, with cells and extracellular matrix, were stained with hematoxylin eosin (HE) and examined in light microscopy. R a roughness values of virgin uncoated TiAl6V4 samples were 0.001 μm, of DCP coated discs 4 μm and of OHAp coated discs 3 μm. The examination of HE stained samples showed a high number of FBGC and monocytes/macrophages on the UUTi samples. On the DCP coated samples there were less FBGC and monocytes/macrophages and on the OHAp coated samples we could not find any FBGC and monocytes/macrophages. The extracellular matrix (ECM) we found on the UUTi samples was finer and thinner than on the coated samples. The ECM was vastly spread and not dense on the UUTi samples in contrast to the calcium phosphate coated samples, where the ECM was much thicker and stronger. The ultrasmooth surface of the uncoated TiAl6V4 samples, a material which is accepted to be biocompatible, evidently induced the differentiation of cells of the monocytic lineage and the formation of FBGC out of the cell populations present in the human bone marrow.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent studies show that macrophage activation and FBGC formation respond to differing polymer fiber diameter [32, 33], surface roughness [34, 35] and geometry [36].”
From Characterization of topographical effects on macrophage behavior in a foreign body response model (2010) · cites this paper as [34]
In the citing paper
“Current research in this area focuses on varying surface chemistries and roughness to modulate the macrophage response toward an M2 phenotype, which will in turn secrete prohealing and anti-inflammatory factors to mitigate the formation of fibrous tissue [5,87,89].”
From Biomaterial based modulation of macrophage polarization: a review and suggested design principles (2015) · cites this paper as [89]
Citations
Cites
Decker, T., & Lohmann-Matthes, M.-L. (1988) · Journal of Immunological Methods · doi:10.1016/0022-1759(88)90310-9 · Cited by 1,359
Chemical modification of titanium surfaces for covalent attachment of biological molecules
Nanci, A., Wuest, J. D., Peru, L., Brunet, P., Sharma, V., Zalzal, S., & McKee, M. D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<324::aid-jbm18>3.0.co;2-l · Cited by 503
Spivak, J. M., Ricci, J. L., Blumenthal, N. C., & Alexander, H. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240902 · Cited by 109
Biocompatibility analysis of different biomaterials in human bone marrow cell cultures
Wilke, A., Orth, J., Lomb, M., Fuhrmann, R., Kienapfel, H., GRISS, P., & Franke, R.-P. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<301::aid-jbm15>3.0.co;2-o · Cited by 83
Self-citationThe effect of starch-based biomaterials on leukocyte adhesion and activation in vitro
Marques, A. P., Reis, R. L., & Hunt, J. A. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-4757-9 · Cited by 20
Cited by
Franz, S., Rammelt, S., Scharnweber, D., & Simon, J. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.078 · Cited by 1,391
Biomaterial based modulation of macrophage polarization: a review and suggested design principles
Sridharan, R., Cameron, A. R., Kelly, D. J., Kearney, C. J., & O’Brien, F. J. (2015) · Materials Today · doi:10.1016/j.mattod.2015.01.019 · Cited by 826
“Current research in this area focuses on varying surface chemistries and roughness to modulate the macrophage response toward an M2 phenotype, which will in turn secrete prohealing and anti-inflammatory factors to mitigate the formation of fibrous tissue [5,87,89].”
BackgroundBiomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
Immune Regulation of Skin Wound Healing: Mechanisms and Novel Therapeutic Targets
Larouche, J., Sheoran, S., Maruyama, K., & Martino, M. M. (2018) · Advances in Wound Care · doi:10.1089/wound.2017.0761 · Cited by 630
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389
“Recent studies show that macrophage activation and FBGC formation respond to differing polymer fiber diameter [32,33], surface roughness [34,35] and geometry [36].”
Metadata
- Authors
- Fink, J., Fuhrmann, R., Scharnweber, T., & Franke, R. P.
- Affiliations
- Universität Ulm (DE)
- Institute for Biological Interfaces, Forschungszentrum Karlsruhe GmbH, Karlsruhe, Germany
- ORCID
- Scharnweber, T.
- Venue
- Clinical Hemorheology and Microcirculation
- Publisher
- SAGE Publications
- Published
- 2008-06
- Volume
- 39
- Issue
- 1-4
- Pages
- 205-212
- ISSN
- 1386-0291 (ISSN-L)
- 1875-8622
- OpenAlex
- W81993338
- Cited by
- 38
- References
- 4
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 1 · 2013: 1
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Clinical Hemorheology and Microcirculation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- monocytes, macrophages, foreign body giant cells, surface roughness, calcium phosphate coatings, hydroxyapatite, monetite, titanium implants, TiAl6V4, bone marrow cells, extracellular matrix, cell differentiation, biocompatibility, cell adhesion, osteoinduction, osteogenic differentiation, osteoclastogenesis
- MeSH terms
- Alloys, Biocompatible Materials, Bone Marrow Cells, Calcium Phosphates, Extracellular Matrix, Humans, Macrophages, Materials Testing, Monocytes, Solubility, Surface Properties, Titanium, X-Ray Diffraction, Giant Cells, Foreign-Body, Durapatite, Cell Culture Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stimulation of monocytes and macrophages: Possible influence of surface roughness. https://app.cochat.ai/papers/10.3233/ch-2008-1090
- The paper
- Fink, J., Fuhrmann, R., Scharnweber, T., & Franke, R. P. (2008). Stimulation of monocytes and macrophages: Possible influence of surface roughness. Clinical Hemorheology and Microcirculation. https://doi.org/10.3233/ch-2008-1090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.