Modulation of cell adhesion by modification of titanium surfaces with covalently attached self‐assembled monolayers
The DOI matches its Crossref record.
Abstract
The surface of titanium has been modified by covalent attachment of an organic monolayer anchored by a siloxane network. This coating completely covers the metal and allows controlled modification of surface properties by the exposed chemical end‐groups of the monolayer forming surfactant. The attachment of such a film allows different bulk materials (e.g., glass and titanium) to have identical surface properties and this can be used in regulating cell adhesion responses. This control over surface functionality can modulate the functions of fibronectin in regulating attachment and neurite formation by neuronal cells. The effect on bacterial adherence that is achieved by using such monolayers to vary surface hydrophilicity is also assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Faucheux, N., Schweiss, R., Lützow, K., Werner, C., & Groth, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.069 · Cited by 729
Senaratne, W., Andruzzi, L., & Ober, C. K. (2005) · Biomacromolecules · doi:10.1021/bm050180a · Cited by 695
Chemical modification of titanium surfaces for covalent attachment of biological molecules
Nanci, A., Wuest, J. D., Peru, L., Brunet, P., Sharma, V., Zalzal, S., & McKee, M. D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<324::aid-jbm18>3.0.co;2-l · Cited by 503
Titanium — the material of choice?
Steinemann, S. G. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00119.x · Cited by 408
Teeth and bones: applications of surface science to dental materials and related biomaterials
Jones, F. (2001) · Surface Science Reports · doi:10.1016/s0167-5729(00)00011-x · Cited by 399
Surface modification of polymers: chemical, biological and surface analytical challenges
Ratner, B. D. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99218-a · Cited by 303
Covalent Attachment of Cell-Adhesive, (Arg-Gly-Asp)-Containing Peptides to Titanium Surfaces
Xiao, S.-J., Textor, M., Spencer, N. D., & Sigrist, H. (1998) · Langmuir · doi:10.1021/la980257z · Cited by 295
Titanium with different oxides: in vitro studies of protein adsorption and contact activation
Wälivaara, B., Aronsson, B.-O., Rodahl, M., Lausmaa, J., & Tengvall, P. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90038-8 · Cited by 208
Biology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
Evaluation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo
Ong, J. L., Carnes, D. L., & Bessho, K. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.053 · Cited by 162
Cytokine and growth factor production by monocytes/macrophages on protein preadsorbed polymers
Bonfield, T. L., Colton, E., Marchant, R. E., & Anderson, J. M. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260702 · Cited by 119
Metadata
- Authors
- Sukenik, C. N., Balachander, N., Culp, L. A., Lewandowska, K., & Merritt, K.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-10
- Volume
- 24
- Issue
- 10
- Pages
- 1307-1323
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1978481656
- Cited by
- 90
- References
- 0
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.