Cited by 119Polymer Surface Interaction StudiesOrthopaedic implants and arthroplastyImmune cells in cancer

Cytokine and growth factor production by monocytes/macrophages on protein preadsorbed polymers

Bonfield, T. L., Colton, E., Marchant, R. E., Anderson, J. M.·1992·Journal of Biomedical Materials Research

Abstract

These studies evaluate the effect of biomedical polymers: Biomer, polydimethyl-siloxane (PDMS), polyethylene, expanded polytetrafluoroethylene (ePTFE), Dacron, and the control polystyrene with or without adsorbed proteins IgG, fibrinogen, and fibronectin on the ability of activated human monocytes/macrophages to produce Interleukin 1 Beta (IL-1-B), Interleukin 6 (IL-6), and Tumor Necrosis Factor Alpha (TNF-A). Monocytes/macrophages incubated on biomedical polymers with or without protein preadsorption produce variable levels of IL-1-B, IL-6, and TNF-A dependent on the polymer and adsorbed protein. IL-6 was produced in the greatest quantity and was the most influenced by protein adsorption. ePTFE and PDMS polymers were least stimulating while polystyrene was the most stimulating of monocyte activity. Adsorbed IgG consistently altered the ability of the polymers to activate monocytes/macrophages to produce cytokines. These studies provide important insight into conditions which modulate monocyte/macrophage activity in response to protein preadsorbed biomedical polymers.

Integrity signals

Registry

Crossref · 10.1002/jbm.820260702

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • IL-6 and TNF-α in vitro macrophage secretion was differential on variant biomedical polymers.

    “IL-6 and TNF-α in vitro macrophage secretion was also found to be differential on variant biomedical polymers.[105]”

    From Foreign body reaction to biomaterials (2008) · cites this paper as [105]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bonfield, T. L., Colton, E., Marchant, R. E., & Anderson, J. M.
Affiliations
Case Western Reserve University (US)
Corresponding author
Anderson, J. M.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1992-07
Volume
26
Issue
7
Pages
837-850
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2150929184
Cited by
119
References
28
Citations by year
2026: 2 · 2023: 1 · 2022: 1 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 9
FWCI
4.48
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (2r01hl025239-19)
  • National Heart, Lung, and Blood Institute (HL25239, HL40047, HL 33849)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
  • Life Sciences › Immunology and Microbiology › Immunology › Immune cells in cancer
Keywords
monocytes, macrophages, cytokine production, growth factors, protein adsorption, biomedical polymers, polydimethylsiloxane, expanded polytetrafluoroethylene, polyethylene, Dacron, polystyrene, IL-1β, interleukin-6, TNF-α, IgG, fibrinogen, fibronectin, biomaterial-immune interaction
MeSH terms
Adsorption, Adult, Cells, Cultured, Humans, Interleukin-1, Macrophages, Monocytes, Polymers, Proteins, Tumor Necrosis Factor-alpha, Interleukin-6

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review